Description
The PowerMir 4.0um High-Power Pulsed Quantum Cascade Laser System is a versatile and user-friendly air-cooled benchtop system designed for lab development purposes. It offers plug-and-play functionality, allowing customers to easily set up and operate the system. This quantum cascade laser (QCL) system is equipped with user-friendly Windows software that controls both temperature and current, ensuring optimal performance and preventing laser damage.
With software modulation or external TTL signal control, users can easily adjust the power output according to their requirements. Additionally, the QCL system's driver can be connected to one or two laser heads, accommodating different projects regardless of wavelength or power. CE-marked and featuring an interlock, this system prioritizes safety and compliance.
PW4000450HCTK1A: PowerMir 4.0um High Power Pulsed Quantum Turnkey System 450mW Circular Beam
Specifications
| Output Power (avg): | 0.45 W |
|---|---|
| Wavelength: | 4 um |
| Pulse Duration: | 300 – 300 ns |
| Tuning Range Around Center Wavelength: | Not Applicable |
| Physical Interface: | USB interface for PC connexion (USB cable supplied); TTL trig IN connector for TTL external signal; TTL trig OUT connector for synchronization |
| Software: | A user friendly Windows software is supplied |
| Input Power: | 24V DC (an AC/DC power transformer is supplied) |
| Dimensions: | Laser head: 20cm x 15cm x 6cm | Driver: 25cm*15cm*6cm |
| Weight: | 925 g |
| Operating Temperature: | +10 to +30 °C |
| Laser Head Cooling: | Air cooled |
| Beam Quality: | TM00 Gaussian beam, M²<1.5 |
| Output Beam Dimension For The Standard Beam Option (window Output): | Typically 3 mm (vertical) x 2 mm (horizontal) |
| Polarization: | Linear vertically polarized (>98%) |
| Reliability: | > 3500 h |
| Mode Of Operation: | Quasi-CW, high duty cycled pulsed |
| Functionalities: | Laser safety, Laser driver (ON/OFF), Laser temperature and TEC control, frequency modulation, duty cycle, external TTL |
Got questions about specs? Use the inquiry form to ask.
Features
- High-power 4 µm Quantum Cascade Laser (QCL): Mid-infrared Fabry-Perot QCL system emitting around 4 µm, with a central wavelength of 4 µm ± 0.1 µm and optical power available across the 3.85 µm to 4.15 µm spectral band.
- QCW / High-Duty-Cycle Pulsed Operation: Quasi-CW operating mode delivers high average optical power while improving wall-plug efficiency and reducing thermal dissipation compared with conventional pulsed MIR laser operation.
- Multiple Output Power Options: Available in configurations delivering >1 W, <500 mW, or <100 mW average optical power, enabling selection for research, industrial, OEM, and export-sensitive applications.
- ITAR-Free MIR Laser Technology: Proudly manufactured in France using proprietary mirSense QCL technology, this ITAR-free quantum cascade laser simplifies international sourcing and integration for many mid-infrared photonics projects.
- Export-Control-Friendly Power Option: The <500 mW version is designed to remain below common dual-use power thresholds, supporting easier deployment in global OEM and industrial systems.
- High Pulse Repetition Frequency: Supports pulse frequencies of >500 kHz, making it suitable for fast mid-IR spectroscopy, high-speed sensing, time-resolved measurements, and industrial monitoring.
- Excellent Beam Quality: Delivers a TM00 Gaussian far-field beam for easier optical alignment, efficient coupling, and reliable integration into MIR spectroscopy and sensing platforms.
- Low Beam Divergence: Standard beam option provides full-angle far-field divergence of <6 mrad horizontal and <4 mrad vertical, helping reduce downstream beam-shaping requirements.
- Optional Circular Beam Output: Available with a proprietary circular beam option that produces a typically <3 mm output beam, offering a more robust alternative to external beam-circularizing optics.
- Standard Beam Output Dimensions: Window-output standard beam is typically 3 mm vertical x 2 mm horizontal, supporting straightforward integration into mid-infrared optical systems.
- High Linear Polarization: Provides >98% vertically linear polarization, ideal for polarization-sensitive MIR spectroscopy, optical filtering, and advanced sensing configurations.
- Reliable Long-Life Operation: Designed for dependable performance with reported reliability of >3500 hours, supporting both laboratory and production environments.
- Reproducible Series Manufacturing: Built for consistent performance from unit to unit, making the laser suitable for OEM integration, multi-system deployment, and scalable production programs.
- Flexible System Configurations: Available as a plug-and-play benchtop turnkey laser system, OEM driver + laser module, or HHL-packaged QCL, allowing customers to choose the best format for R&D, prototyping, or embedded instrumentation.
- Efficient Thermal Management: QCW operation and optimized QCL design reduce heat load, helping simplify thermal control and improve overall system efficiency.
- Mid-Infrared Spectroscopy Ready: Optimized for MIR spectroscopy, trace gas detection, chemical sensing, environmental monitoring, industrial process control, and scientific research applications requiring high-power emission near 4 µm.
- OEM-Friendly MIR Source: Compact laser packaging options, high repetition rate, stable beam characteristics, and reproducible specifications make this 4 µm QCW QCL well suited for integration into commercial instruments and custom photonics platforms.
- High-Performance Proprietary Technology: Based on mirSense PowerMir high-power pulsed Fabry-Perot QCL technology, delivering strong average output power, efficient operation, and robust mid-infrared laser performance.
Applications
Applications for 4 µm QCW Quantum Cascade Laser Systems
- Mid-Infrared Gas Sensing: High-power 4 µm QCW QCL source for sensitive detection of gases with absorption features in the 3.85–4.15 µm spectral region.
- Trace Gas Analysis: Suitable for trace-level molecular detection in industrial, environmental, laboratory, and research instrumentation using mid-IR absorption spectroscopy.
- Photoacoustic Spectroscopy: Powerful pulsed mid-infrared laser source for compact photoacoustic gas analyzers requiring high optical power and efficient thermal management.
- Tunable Diode Laser Absorption Spectroscopy: Laser source for TDLAS-based systems where narrowband MIR emission, high duty-cycle pulsed operation, and stable output are required.
- Open-Path Gas Monitoring: Mid-IR laser transmitter for open-path and remote gas detection systems in industrial plants, refineries, chemical facilities, and perimeter monitoring applications.
- Standoff Chemical Detection: High-power 4 µm quantum cascade laser for remote identification of chemical vapors, hazardous substances, and industrial emissions.
- Industrial Emissions Monitoring: Applicable to continuous emissions monitoring systems, stack gas analysis, process exhaust monitoring, and leak detection platforms.
- Environmental Monitoring: Used in atmospheric sensing, air-quality monitoring, greenhouse gas research, and field-deployable MIR sensor systems.
- Combustion Diagnostics: Mid-infrared source for studying combustion chemistry, hot gas flows, flame diagnostics, exhaust composition, and high-temperature reaction monitoring.
- Process Analytical Technology: Integrated into real-time process control systems for chemical production, petrochemical processing, pharmaceutical manufacturing, and specialty gas monitoring.
- FTIR and MIR Spectroscopy Enhancement: High-brightness 4 µm QCL source for mid-infrared spectroscopy setups requiring stronger illumination than broadband thermal sources.
- ATR Spectroscopy: Laser source for attenuated total reflection measurements of liquids, polymers, coatings, thin films, and chemical samples with MIR absorption near 4 µm.
- Molecular Spectroscopy Research: Suitable for laboratory spectroscopy of gases, vapors, and molecular transitions in the mid-infrared fingerprint and ro-vibrational absorption regions.
- Cavity-Enhanced Spectroscopy: Compatible with high-sensitivity cavity ring-down spectroscopy and cavity-enhanced absorption spectroscopy systems using MIR laser excitation.
- Isotope Ratio Analysis: Can be used in laser-based isotope measurement systems when target isotopologue absorption lines overlap the 4 µm emission band.
- Defense and Security Sensing: ITAR-free MIR QCL technology for chemical threat detection, surveillance sensor development, and field-deployable security instrumentation.
- MWIR Sensor Testing: High-power 4 µm source for testing, alignment, calibration, and characterization of mid-wave infrared detectors, cameras, focal plane arrays, and optical systems.
- Infrared Countermeasure and DIRCM Research: Applicable to laboratory evaluation of MWIR emitters, beam delivery systems, and infrared sensor response testing where export-compliant sources are needed.
- Free-Space Optical Experiments: Mid-infrared laser source for research in atmospheric transmission, free-space optical links, beam propagation, and MWIR communication feasibility studies.
- Nonlinear Optics and MIR Photonics: High-power pulsed QCL source for nonlinear mid-infrared experiments, waveguide coupling, photonic integrated circuit testing, and MIR component evaluation.
- Laser Beam Delivery Development: Useful for testing MIR-compatible lenses, mirrors, fibers, coatings, windows, beam expanders, and optical assemblies at approximately 4 µm.
- Biomedical and Breath Analysis Research: MIR laser source for non-invasive breath diagnostics and biomedical spectroscopy studies where target biomarkers absorb near the 4 µm wavelength range.
- Pharmaceutical and Chemical Identification: Enables MIR absorption measurements for material identification, contamination analysis, and chemical quality control in laboratory and production environments.
- OEM Gas Analyzer Integration: Available as HHL-packaged laser, OEM driver plus laser module, or turnkey system for integration into commercial MIR sensing instruments.
- High-Power Mid-IR Instrument Developm
Frequently Asked Questions
What is the mirSense PowerMir 4 µm QCW quantum cascade laser?
What output power is available from this 4 µm mid-IR QCL?
What does QCW operation mean for this quantum cascade laser?
Is the 4 µm PowerMir QCL ITAR free and export controlled?
What beam quality, divergence, and polarization does the 4 µm QCW QCL provide?
What package and system configurations are available for this 4 µm QCL?
What applications are suitable for a high-power 4 µm mid-infrared QCL?
Got more questions? Use the inquiry form to ask the supplier directly.
Similar Products
Your inquiry has been received.
Create an account by adding a password
Why create an account?
- Auto-complete inquiry forms
- View and manage all your past messages
- Save products to your favorites
- Close your account anytime — no hassle