Description
The Ocean NR-512-2.2 High Gain spectrometer delivers maximum sensitivity across an extended 900–2200 nm wavelength range, making it ideal for advanced NIR applications where weak signals and low-concentration samples must be measured with accuracy. Combining precision, consistency, and adaptability, the NR-512-2.2 High Gain near-infrared spectrometer is engineered to provide superior signal-to-noise performance in demanding laboratory and industrial environments.
Built around a high-performance 512-element InGaAs array detector in a high-gain configuration, the NR-512-2.2 High Gain offers excellent baseline stability, ultra-low noise, and reproducible results across a wide dynamic range. Configurable entrance slits allow users to fine-tune the balance between spectral resolution and throughput, ensuring optimal performance for a variety of measurement requirements.
The NR-512-2.2 High Gain NIR compact spectrometer is designed with a compact, integration-ready footprint and supports versatile connectivity via USB, Gigabit Ethernet, and RS-232, along with multiple trigger modes for synchronized acquisition. Seamless integration with the OceanDirect™ SDK empowers developers with advanced control, workflow automation, and OEM system embedding.
With its combination of extended spectral reach and enhanced sensitivity, the NR-512-2.2 High Gain spectrometer is ideally suited for applications such as pharmaceutical QA, bioprocess monitoring, polymer and plastic identification in recycling, liquid concentration analysis, and advanced process monitoring. Its adaptability and rugged reliability make it a critical tool for professionals requiring accurate, repeatable NIR measurements across a broad wavelength range.
Ocean NR-512-2.2 High Gain Spectrometer for NIR Analysis
Specifications
| Wavelength Range (reflectance): | 900 – 2190 nm |
|---|---|
| Resolution: | 5.41 nm |
| Minimum Integration Time: | 1 ms |
| Optical Resolution (w/ 25 µm Slit): | as low as 5.41 nm (FWHM) |
| Signal To Noise Ratio (single Scan): | 2,788:1 |
| Integration Time: | 1 ms - 120 s |
| Dynamic Range (single Scan): | 10,323:1 |
| Stray Light: | 2.6 AU |
| Scan Rate: | 242 Hz |
| Thermal Wavelength Drift: | 0.01 nm/°C |
| A/D Resolution: | 16-bit |
| Interfaces: | USB, RS-232, Ethernet |
| Connector: | 16 pin Samtec TFM, RS-232, SMA 905 (input fiber), USB Type-C |
| Dimensions: | 182.25 mm × 109.19 mm × 46.45 mm |
| Weight: | 1.17 kg |
| High Speed Averaging Mode: | Yes |
Got questions about specs? Use the inquiry form to ask.
Features
- Wide NIR Wavelength Coverage: Choose from two models – NR512-1.7 (900-1700 nm) and NR512-2.2 (897-2188 nm) – for versatile near-infrared analysis across a broad spectral range.
- Exceptional Sensitivity & High Gain Options: High gain configurations available for detecting low-concentration samples and weak signals, ideal for challenging applications such as low-reflectance or strongly absorbing materials.
- Superior Optical Resolution: Achieve optical resolution as low as 2.85 nm (FWHM), enabling precise identification of subtle spectral features in complex samples.
- Fast Integration Times: Flexible integration times from 1 ms to 8 s (model dependent) support both rapid and long-duration measurements for dynamic or static samples.
- Outstanding Signal-to-Noise Ratio: SNR up to 10,000 (model and version dependent) delivers cleaner spectra and lower limits of detection for reliable results.
- Thermoelectric Cooling for Enhanced Stability: Detector cooling to -25°C (model dependent) minimizes dark current and thermal noise, ensuring stable performance in demanding environments.
- Advanced Order-Sorting Filters: NR512-1.7 features a longpass filter (>830 nm); NR512-2.2 includes an improved order-sorting filter (OD>4) for superior spectral purity.
- Customizable Entrance Aperture: Standard 25 μm slit with other sizes available to optimize light throughput and resolution for your application.
- Robust for Lab and Industrial Use: Engineered for both laboratory research and process line integration, including materials characterization, plastics identification in recycling, and concentration measurements in liquids.
- High-Speed Measurements: Ideal for real-time analysis of moving samples or dynamic processes, supporting efficient quality control and authentication workflows.
- Reliable Data for Quality Control: Cleaner data and high gain options enable accurate measurement of key quality factors, supporting authentication and quality assurance in critical applications.
- Global Support and Expertise: Backed by Ocean Optics’ worldwide support network and application scientists for expert guidance and technical assistance.
Applications
The Ocean NR-512-2.2 High Gain spectrometer is designed for advanced near-infrared (NIR) analysis across research, industrial, and OEM applications, providing maximum sensitivity and extended wavelength coverage from 900–2200 nm. Its high-gain configuration enhances the detection of weak signals and low-concentration analytes while maintaining stable, reproducible performance in demanding environments. Common applications include:
- Materials Characterization – Detect faint spectral features and characterize complex materials with greater accuracy.
- Plastic Identification in Recycling – Differentiate between polymers across an extended NIR range, even in low-signal conditions.
- Liquid Concentration Measurement – Quantify low-level concentrations of substances in liquids with improved sensitivity for QA and process control.
- Pharmaceutical Analysis – Monitor trace ingredients and excipients in formulations with confidence.
- Food Quality Assessment – Evaluate subtle differences in moisture, fat, and protein content in food products.
- Environmental Monitoring – Detect pollutants and contaminants at lower concentrations in environmental samples.
Why Choose the Ocean NR-512-2.2 High Gain?
With its extended 900–2200 nm coverage and high-gain detector configuration, the NR-512-2.2 High Gain provides superior signal-to-noise ratio, baseline stability, and reproducibility. Its enhanced sensitivity makes it the ideal choice for applications requiring trace-level detection and extended spectral reach. Whether deployed in laboratory research, industrial QA, or inline monitoring, it offers the performance, reliability, and adaptability demanded by today’s most challenging NIR spectroscopy applications.
Frequently Asked Questions
What are the wavelength ranges available for the NR near-infrared spectrometers?
What applications are the NR compact spectrometers suitable for?
What is the optical resolution of the NR spectrometers?
How does the NR infrared spectrometer ensure thermal stability?
What is the integration time range for the NR spectrometers?
What are the benefits of high gain configurations in NR spectrometers?
How can I get more information about the NR spectrometers?
Got more questions? Use the inquiry form to ask the supplier directly.
Similar Products
Your inquiry has been received.
Create an account by adding a password
Why create an account?
- Auto-complete inquiry forms
- View and manage all your past messages
- Save products to your favorites
- Close your account anytime — no hassle