Description

SmartEngine UV–VNIR Spectrometer Overview

The SmartEngine UV–VNIR Spectrometer from Evolve Sensing is a versatile and high-performance solution designed for precise spectral analysis across the ultraviolet, visible, and near-infrared ranges. Built on a compact Czerny–Turner optical platform, this spectrometer series is engineered to meet the demanding requirements of laboratory research, industrial quality control, and OEM system integration. Its robust construction and advanced sensor technology make it a reliable choice for a wide array of applications, including semiconductor inspection, display and LED testing, thin-film and coating measurement, biomedical diagnostics, and environmental monitoring.

The SmartEngine series stands out for its flexibility and adaptability, offering multiple sensor options such as front-illuminated CCD, UV-enhanced CCD, and fast-exposure CMOS, as well as NIR-enhanced back-illuminated CCDs. This allows users to select the optimal configuration for their specific measurement needs, whether prioritizing sensitivity, speed, or spectral range. The spectrometer covers a broad wavelength range from 180 nm to 1100 nm, with various models tailored for different spectral windows and resolutions, making it suitable for both routine and specialized analytical tasks.

Designed with user convenience in mind, the SmartEngine spectrometer features USB-powered operation and programmable I/O, facilitating seamless integration into laboratory setups, automated production lines, or embedded OEM systems. Its compact footprint (as small as 110 × 86 × 32.4 mm) and lightweight design (0.4 kg) ensure easy installation even in space-constrained environments. The spectrometer’s high signal-to-noise ratio (up to 500), wide dynamic range (up to 6000), and excellent thermal stability (<0.04 nm/°C) guarantee consistent, accurate results even under varying operating conditions.

With a choice of up to 15 gratings optimized for different spectral regions, and integration times ranging from 0.1 ms to 65 seconds depending on the sensor, the SmartEngine UV–VNIR Spectrometer delivers exceptional versatility. Its low stray light (<0.2–0.45%) and low dark noise further enhance measurement fidelity, making it a dependable tool for both research and industrial environments. Whether used for process monitoring, quality assurance, or advanced scientific investigations, the SmartEngine series provides the performance and reliability required for today’s most challenging spectroscopic applications.

SmartEngine UV-VNIR Series Spectrometer

Specifications

Wavelength Range (reflectance): 180 – 1100 nm
Resolution: 0.2 nm
Resolution: 0.2–10.5 nm (depends on slit & grating)
Dimensions: 110 × 86 × 32.4 mm (Type I) / 110 × 86 × 35.4 mm (Type II)
Detector Type: CCD (front/back-illuminated, UV/NIR-enhanced) or CMOS
Cooling: Passive (no active TEC)
Signal-To-Noise Ratio (SNR): 200–500 (model dependent)
Thermal Stability: <0.04 nm / °C
A/D Resolution: 16-bit
Integration / Scan Time Range: 0.1 ms – 24 s
Minimum Scan Time: 0.0001 s
Dynamic Range: 1700–6000
Optical Resolution (FWHM): 0.2–10.5 nm
Stray Light: < 0.2–0.45 %
Interfaces: USB 2.0, external I/O (6 GPIO, trigger, lamp control)
Connector Type: SMA905 / FC-PC fiber
Power Requirements: +5 V DC @ 300 mA (USB)
Operating Temperature: 0 °C – 50 °C
Storage Temperature: –30 °C – 70 °C
Environmental Limits: 0–90 % RH non-condensing
A/D Converter Type: 16-bit ADC
Weight: 0.4 kg

Got questions about specs? Use the inquiry form to ask.

Document icon Download Data Sheet Download icon

Features

  • Wavelength coverage: 180–1100 nm
  • Optical resolution: 0.2–10.5 nm (depends on slit width and grating)
  • Multiple sensor options: CCD (front-/back-illuminated, UV-enhanced) and CMOS (high-speed, high-resolution)
  • Integration time: 0.1 ms – 24 s (sensor dependent)
  • 16-bit, 15 MHz A/D converter for precise digital output
  • USB 2.0 high-speed interface (480 Mbps)
  • 8-pin I/O port with 6 programmable digital lines for external trigger and lamp control
  • Flash ROM storage for wavelength, linearity, and intensity calibration parameters
  • Supports multiple trigger modes and ring-buffer operation
  • Stores up to 4,000 spectra for continuous acquisition
  • Compact, rugged construction resistant to humidity, shock, and vibration
  • Boot-up time < 4 s

Applications

  • UV–VIS–NIR Spectroscopy and Optical Characterization
    Ideal for precise spectral analysis across the ultraviolet, visible, and near-infrared regions (180–1100 nm), supporting research and development in physics, chemistry, and materials science.
  • Semiconductor, Display, and LED Testing
    Enables accurate measurement of emission spectra, color coordinates, and quality control for LEDs, OLEDs, and display panels, as well as wafer and chip inspection in semiconductor manufacturing.
  • Thin-Film, Coating, and Color Measurement
    Facilitates non-destructive evaluation of thin-film thickness, uniformity, and optical properties, and provides precise color analysis for paints, coatings, plastics, and textiles.
  • Biomedical and Life Sciences Sensing
    Supports absorbance, fluorescence, and reflectance measurements for DNA/RNA quantification, protein assays, tissue analysis, and point-of-care diagnostics.
  • Environmental Monitoring and Sensing
    Enables detection and quantification of pollutants, water quality analysis, air monitoring, and soil characterization through spectral fingerprinting.
  • Process and Quality Control Monitoring
    Integrates into industrial automation systems for real-time monitoring of production lines, ensuring consistent product quality and process optimization.
  • OEM and Embedded System Integration
    Compact form factor and programmable I/O make it suitable for integration into analytical instruments, handheld devices, and custom OEM solutions.
  • Pharmaceutical Analysis
    Used for raw material verification, content uniformity, and impurity detection in pharmaceutical manufacturing and quality assurance.
  • Food and Agriculture Analysis
    Assists in monitoring food quality, detecting adulterants, and analyzing crop health and composition using non-destructive spectral techniques.
  • Forensic and Security Applications
    Provides rapid identification of substances, counterfeit detection, and trace evidence analysis in forensic laboratories and security screening.
  • Material Science and Nanotechnology Research
    Enables characterization of nanomaterials, polymers, and advanced composites through absorption, transmission, and reflectance spectroscopy.
  • Solar Cell and Photovoltaic Testing
    Measures spectral response, quantum efficiency, and performance of solar cells and photovoltaic materials.
  • Laser and Light Source Characterization
    Analyzes wavelength, bandwidth, and stability of lasers, LEDs, and other light sources for research and industrial applications.
  • Academic and Educational Use
    Serves as a versatile teaching tool for laboratory experiments in physics, chemistry, biology, and engineering courses.

Frequently Asked Questions

What is the SmartEngine (SE) Series Spectrometer?
The SmartEngine (SE) Series spectrometers are high-performance spectral analysis devices featuring a compact, rugged Czerny–Turner optical system. They are designed for UV, visible, and NIR applications and are powered by USB.
What wavelength range does the SmartEngine Series cover?
The SmartEngine Series covers a wavelength range of 180–1100 nm.
What sensor options are available for the SmartEngine Series?
The SmartEngine Series offers multiple sensor options, including CCD (front-/back-illuminated, UV-enhanced) and CMOS (high-speed, high-resolution) sensors.
How is the SmartEngine Series powered?
The SmartEngine Series is powered entirely by USB, requiring a +5 V DC power supply with a typical current of 300 mA.
What is the integration time range for the SmartEngine Series?
The integration time for the SmartEngine Series ranges from 0.1 ms to 24 seconds, depending on the sensor used.
What are the environmental operating conditions for the SmartEngine Series?
The SmartEngine Series operates in temperatures ranging from 0 to 50 °C and can be stored in temperatures from -30 to 70 °C.
What is the boot-up time for the SmartEngine Series?
The boot-up time for the SmartEngine Series is less than 4 seconds.

Got more questions? Use the inquiry form to ask the supplier directly.