Description

The Ocean HR2 is engineered for high-resolution spectroscopy, providing exceptional performance for a variety of scientific and industrial applications. With an optical resolution of 1.33 nm (FWHM) and a dynamic range of 25,800:1 in a single scan, the HR2 delivers precise, reliable spectral measurements even in demanding environments.

Covering a wavelength range of ~190–1100 nm (depending on configuration), the HR2 supports integration times from 1 µs to 2 s, offering flexibility for both ultrafast acquisitions and longer measurements. It achieves an SNR up to 25,800:1 per second with High-Speed Averaging Mode, while thermal stability of 0.02 nm/°C ensures consistent results across varying ambient conditions.

Compact and integration-ready, the HR2 provides flexible connectivity through USB Type-C, RS-232, and Ethernet interfaces and includes multiple trigger modes for synchronized data acquisition. Full support for the OceanDirect™ SDK gives developers advanced tools for controlling acquisition parameters, automating workflows, and embedding the spectrometer into custom laboratory or OEM systems.

The HR2 is ideally suited for applications such as plasma monitoring, pharmaceutical analysis, and environmental monitoring, where high-resolution performance, reliability, and reproducibility are essential. Its combination of fast acquisition capability, broad wavelength coverage, and exceptional dynamic range makes it a versatile solution for both research and applied use.

Ocean HR2 Spectrometer – Rapid, Stable, High-Resolution Performance

Specifications

Wavelength Range (reflectance): 190 – 1100 nm
Resolution: 0.14 nm
Integration Time: 1 µs - 2 s
Signal To Noise Ratio (max. Per Second W/ High Speed Averaging Mode): 25800:1
Signal To Noise Ratio (single Scan): 380:1
Dynamic Range: 3400:1 (single scan)
Stray Light: 2 AU
Thermal Wavelength Drift: 0.02 nm/°C
High Speed Averaging Mode: Yes
Temperature (storage): -30 °C to 70 °C
Temperature (operation): 0 °C to 55 °C
Interfaces: USB, RS-232, Ethernet
Connector: USB Type-C, Samtec™ TFM-108-02-L-DH, RJ45
Dimensions: 149.0 mm x 106.4 mm x 48.2 mm
Weight: 931 g

Got questions about specs? Use the inquiry form to ask.

Document icon Download Data Sheet Download icon

Features

  • Exceptional Signal-to-Noise Ratio: Up to 25,800:1 per second with High-Speed Averaging Mode for clear and accurate data.
  • Thermal Stability: Minimal wavelength drift ensures reliable performance in varying environmental conditions.
  • Versatile Connectivity: USB Type-C, RS-232, and Ethernet interfaces support diverse integration needs.
  • Comprehensive Software Support: OceanDirect SDK facilitates customization and data analysis.
  • Rapid Acquisition Speed: Achieve integration times as fast as 1 µs, making it ideal for fast-paced applications.
  • Wide Wavelength Range: Covers approximately 190-1100 nm, suitable for a variety of applications.
  • High Optical Resolution: Choose from different slit width sizes to manage throughput and optical resolution, achieving 0.14-1.20 nm (FWHM) with a 25 µm slit.
  • High Dynamic Range: Offers a dynamic range of 3400:1 in a single scan.
  • Compact and Lightweight Design: Dimensions of 149.0 mm x 106.4 mm x 48.2 mm and weighs 931 g, making it easy to integrate into various setups.

Applications

  • Plasma Monitoring: Analyze emission spectra from plasma sources for process control.
  • Pharmaceutical Analysis: Monitor active pharmaceutical ingredients and excipients in formulations.
  • Environmental Monitoring: Measure pollutants and contaminants in environmental samples.
  • Material Characterization: Assess the properties of materials through spectral analysis.
  • Chemical Analysis: Conduct detailed spectral analysis of chemical substances.

Frequently Asked Questions

What is the wavelength range of the HR2 Spectrometer?
The HR2 Spectrometer covers a wavelength range of approximately 190-1100 nm.
What is the integration time range for the HR2 Spectrometer?
The integration time for the HR2 Spectrometer ranges from 1 µs to 2 seconds.
What interfaces does the HR2 Spectrometer support?
The HR2 Spectrometer supports USB, RS-232, and Ethernet interfaces.
How does the HR2 Spectrometer ensure thermal stability?
The HR2 Spectrometer ensures thermal stability with a thermal wavelength drift of 0.02 nm/°C.
What is the signal-to-noise ratio of the HR2 Spectrometer?
The HR2 Spectrometer has a signal-to-noise ratio of 25800:1 with High Speed Averaging Mode and 380:1 for a single scan.
What are the dimensions and weight of the HR2 Spectrometer?
The HR2 Spectrometer measures 149.0 mm x 106.4 mm x 48.2 mm and weighs 931 g.
What software comes with the HR2 Spectrometer?
Each HR2 Spectrometer comes with OceanDirect, a cross-platform Software Developers Kit with an Application Programming Interface.

Got more questions? Use the inquiry form to ask the supplier directly.

Similar Products