APE Levante IR - Picosecond Pumped OPO
For pricing, technical or any other questions please contact the supplier
- No registration required
- No markups, no fees
- Direct contact with supplier
-
Ships from:
United States
-
Sold by:
-
On FindLight:
since 2014
Description
Levante IR is a cutting-edge, synchronously pumped Optical Parametric Oscillator (OPO) engineered for seamless integration with mode-locked lasers operating at a wavelength of 1 µm. Designed with innovation and user-friendliness in mind, Levante IR offers an impressive output wavelength spanning approximately 1300 nm to 5000 nm. This tunable IR OPO is available in both picosecond and femtosecond versions, ensuring versatility and adaptability for various scientific and industrial applications.
The synchronous pumping scheme of Levante IR ensures a jitter-free and stable repetition rate that matches the pump laser's rate. This precision is crucial for applications demanding high stability and accuracy. The automated wavelength tuning feature simplifies the process, allowing users to effortlessly adjust the OPO to the desired wavelength range.
Equipped with a user-friendly control software, Levante IR provides real-time data display and facilitates remote control through a TCP/IP-based standard software interface. This capability enables users to design automated measurement routines easily, utilizing protocol templates compatible with popular programming languages like C++, C#, LabVIEW, Python, Matlab, and Ruby. This flexibility is ideal for researchers and engineers looking to integrate the OPO into complex experimental setups.
The Levante IR's Signal beam offers a wavelength range of 1315 to 2000 nm, while the Idler output spans 2150 to 5000 nm. When paired with APE's HarmoniXX series, the extended wavelength range from 660 nm to 15 µm can be achieved, providing additional versatility for applications such as vibrational spectroscopy. The integration of wavelength converters like SHG, THG, and DFG further enhances the system's capability, making Levante IR a comprehensive solution for advanced optical research.
APE Levante IR - Picosecond Pumped OPO
Specifications |
|
---|---|
Repetition Rate: | 75 MHz |
Total Tuning Range: | 1315 – 4800 nm |
Core Tuning Range: | 1315 – 2000 nm |
Output Power (avg): | 1.5 W |
Pulse Duration: | 2000 fs |
Idler Polarization: | N/A |
Signal Polarization: | N/A |
Features
- Automated Wavelength Tuning: The Levante IR features fully automated wavelength tuning, ensuring precise and easy adjustments for various applications.
- Synchronous Pumping Scheme: Utilizes a jitter-free and stable repetition rate identical to the pump laser, available in both picosecond and femtosecond versions.
- Integrated Spectrometer: Built-in spectrometer for feedback during wavelength tuning, enhancing accuracy and performance.
- Standard Software Interface (TCP/IP): Comes with a user-friendly control software and a TCP/IP-based interface, allowing for remote control and automation of measurement routines.
- Wide Wavelength Range: Signal beam output from 1315 to 2000 nm and Idler output from 2150 to 5000 nm, ideal for IR applications like vibrational spectroscopy.
- Extended Wavelength Range: When combined with APE's HarmoniXX series, generates wavelengths from 660 nm to 15 μm using SHG, THG, and DFG converters.
- Easy-to-Use Control Interface: Includes real-time data display for seamless operation and monitoring.
- High Power Output: Provides >1.5 W at 1500 nm (Signal) and >0.6 W at 2500 nm (Idler) when pumped with 7.5 W, 2 ps; higher outputs achievable with increased pump power.
- Compatibility: Requires an IR ps-Laser or IR fs-Laser with a wavelength range of 1030 to 1064 nm and various pulse widths and repetition rates.
- Software and Remote Control: Includes software for operation and offers remote control capabilities via TCP/IP for flexible integration.
Applications
- Automated wavelength tuning
- Synchronous pumping scheme
- Standard Software Interface (using TCP/IP)
- Integrated spectrometer for OPO Signal wavelength range
- Levante IR is a synchronously pumped Optical Parametric Oscillator with an innovative and user-friendly design. Mode-locked lasers with an output wavelength of 1 µm are suitable as pump lasers. The output wavelength ranges from approx. 1300 nm to 5000 nm.
- The tunable IR OPO is available as picosecond and femtosecond version. Its synchronous pumping scheme provides a jitter-free and stable repetition rate that is identical to the repetition rate of the pump laser.
- Levante IR: Tunable OPO for IR Pump Laser
- All models come with an easy to use control software, allowing for real-time data display. Furthermore, the TCP/IP-based standard software interface by APE makes it straightforward to set up remote control. This allows you, for example, to design your own automated measurement routines. Simply use our protocol templates for rapid configuration with familiar programming languages, including C++, C#, LabVIEW, Python, Matlab, and Ruby.
- The output wavelength range for the Signal beam is 1315 ... 2000 nm and the wavelength for the Idler output ranges from 2150 ... 5000 nm. This is ideal for applications that require tunable radiation in the IR range, e.g. vibrational spectroscopy. The wavelength tuning is fully automated.
- An extended wavelength range from 660 nm to 15 μm can be generated when Levante IR is operated in combination with APE's HarmoniXX series. Wavelength converters SHG (Second Harmonic Generation), THG (Third Harmonic Generation) and DFG (Difference Frequency Generation) are available.
- Control Software and TCP/IP Standard Software Interface
- Automated Tuning for IR Wavelength Range
- Software-Interface: The Levante IR comes with an easy-to-use control interface with real-time data display.
Frequently Asked Questions
The Levante IRNSP ps is a synchronously pumped OPO (optical parametric oscillator) with a mode-locked picosecond laser emitting at 1 μm as fixed wavelength pump source.
The accessible wavelength range for the Signal output is 1315 ... 2000 nm.
The wavelength range for the optional Idler output is 2150 ... 4800 nm (when pumped @ 1031 nm).
The Levante IR is ideal for applications that require tunable light in the IR, e.g. vibrational spectroscopy. It can be used in spectroscopy, nonlinear optics, biomedical engineering, and microscopy.
The required pump laser for the Levante IR is an IR ps-Laser with a wavelength of 1030 ... 1064 nm, pulse duration of 1 ... 10 ps, and repetition rate of 75 ... > 80 MHz (fixed at the time of order).