Description
It is good to have plenty of options at hand. Suitable for the characterization of virtually any ultrafast pulsed laser, the pulseCheck autocorrelator from APE covers the broadest possible range of wavelengths and pulse widths. This flexibility is achieved by using exchangeable Optics Sets, typically consisting of a nonlinear crystal and a dedicated detector module.
APE pulseCheck The Modular Autocorrelator
Specifications
| Device Type: | Autocorrelator | 
|---|---|
| Measurable Pulse Width: | 10 – 500 fs | 
| Wavelength Range: | 200 – 12000 nm | 
| Input Polarization: | Horizontal, Vertical | 
Features
- Exchangeable Optics Sets for broadest spectrum coverage from 200 nm to 12 μm
 - Pulse widths from as low as <10 fs all the way up to 500 ps
 - Ultra-precise delay resolution
 - Toggle between interferometric and intensity autocorrelation
 - Wide range of sensitivity levels covered with PMT, PD, and TPA
 - Automatic phase matching
 - Gaussian Sech2, and Lorentzian fitting routines
 - Ready to use software and USB interface
 - TCP IP remote control with standardized command set for easy programming
 - NIST traceable calibrationOption
 - FROG for complete pulse characterization
 
Frequently Asked Questions
What is the pulse width measurement range of the pulseCheck autocorrelator?
                        The pulse width measurement range of the pulseCheck autocorrelator varies depending on the model, ranging from <10 fs to 500 ps.
                    
                What types of detectors are available for the pulseCheck autocorrelator?
                        The pulseCheck autocorrelator offers three types of detectors: photodiode (PD), photomultiplier (PMT), and two photon absorption (TPA).
                    
                What is the sensitivity range of the detectors for the pulseCheck autocorrelator?
                        The sensitivity range of the detectors for the pulseCheck autocorrelator varies depending on the type, with the PMT having the highest sensitivity up to 10-6 W2 and the TPA having high sensitivity up to 10-2 W2.
                    
                What is the FROG option for the pulseCheck autocorrelator?
                        The FROG option is a feature that allows for complete pulse characterization.
                    
                What is the range of wavelengths covered by the pulseCheck autocorrelator?
                        The pulseCheck autocorrelator covers the broadest possible range of wavelengths from 200 nm to 12 μm with exchangeable Optics Sets.
                    
                Similar Products
                            ROC | Compact Autocorrelator for Ultrafast Laser Pulse Measurement
                        
                        
                            Axiom Optics
                        
                    
                                                        
                        
                            Blueback Spider - Based Laser Pulse Characterization Device
                        
                        
                            RPMC Lasers, Inc.
                        
                    
                                                        
                        
                            d-cycle
                        
                        
                            Sphere Ultrafast Photonics, S. A.
                        
                    
                                                        
                        
                            d-shot
                        
                        
                            Sphere Ultrafast Photonics, S. A.
                        
                    
                                                        
                        
                            APE Spider IR 1 μm Central Wavelength
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                                                        
                        
                            APE FC Spider VIS
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                                                        
                        
                            APE FC Spider NIR
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                                                        
                        
                            APE Second Harmonic Generation FROG
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                                                        
                        
                            APE Mini TPA Compact And Tuning-free Autocorrelator
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                                                        
                        
                            APE Carpe Microscopy Autocorrelator
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                                                        
                        
                            d-scan
                        
                        
                            Sphere Ultrafast Photonics, S. A.
                        
                    
                                                        
                        
                            APE  peakDetect
                        
                        
                            Applied Physics & Electronics, Inc.
                        
                    
                        Thank You!
        Your inquiry has been received.
Create an account by adding a password
Why create an account?
- Auto-complete inquiry forms
 - View and manage all your past messages
 - Save products to your favorites
 - Close your account anytime — no hassle