Reflectometers and Transmissometers (Wavelength Bands: 1330 nm)

ET-100 Emissometer

ET-100 Emissometer

The ET-100 Emissometer is a cutting-edge instrument designed to measure directional reflectance across a wide spectral range of 1.5 to 21 μm. By analyzing these reflectance values, the ET-100 calculates both ...

Inquire Price FAST RESPONSE
Sold by: Surface Optics Corp Ships from: United States
Specifications
Calculated Value: Directional thermal emissivity at 20º, directional thermal emissivity at 60º, hemispherical thermal emissivity
Wavelength Bands: 1.5-2.0, 2.0-3.5, 3.0-4.0, 4.0-5.0, 5.0-10.5, 10.5-21 µm
Angle Of Incidence: 20º & 60º from normal incidence
ASTM Standards: E903
Calibration Coupon: Specular Gold
410-DHR Reflectometer

410-DHR Reflectometer

The 410-DHR is a groundbreaking portable device designed for the precise verification of optical properties of large objects in the field. This innovative product is the result of a collaborative effort between the ...

Inquire Price FAST RESPONSE
Sold by: Surface Optics Corp Ships from: United States
Specifications
Wavelength Bands: 1000-1700 nm, 1700-2500, 3.0-4.0 um, 3.0-5.0 um, 4.0-5.0 um, 8.0-12.0 um
Angle Of Incidence (from Normal): 20 deg
Accuracy: 0.03 (abs. refl. units)
Repeatability: 0.005 units
Beam Spot Size: 12.7 mm
410-Solar Reflectometer

410-Solar Reflectometer

The 410-Solar Reflectometer conforms to ASTM E903 and C1549, the standard test methods for solar reflectance measurements. Measures reflectance at near-normal incidence for seven spectral bands. The 410-Solar ...

Inquire Price FAST RESPONSE
Sold by: Surface Optics Corp Ships from: United States
Specifications
Repeatability:: ±.005 units
Run Time:: 2 hours on one battery
Operating Temp:: 0° to 40°C
Sample Temperature:: Ambient or heated/cooled to 0 – 100°C
Time Between Measurements:: 2 seconds
410-Solar-I Reflectometer

410-Solar-I Reflectometer

The 410-Solar-i Reflectometer conforms to ASTM E903 and C1549, the standard test methods for solar reflectance measurements. Measures total reflectance at near-normal incidence for seven spectral bands. Choose from ...

Inquire Price FAST RESPONSE
Sold by: Surface Optics Corp Ships from: United States
Specifications
Measured Parameter:: Directional hemispherical reflectance (DHR)
Measured Value:: Absolute reflectance (0-1), Diffuse Reflectance
Calculated Value:: Total Solar reflectance, Solar absorptance, specular reflectance
Wavelength Bands:: 335-380, 400-540, 480-600, 590-720, 700-1100, 1000-1700, 1700-2500 (nm)
Angle Of Incidence:: 20º from normal incidence
On FindLight marketplace you will find 4 different Reflectometers and Transmissometers (Wavelength Bands: 1330 nm) from top global suppliers. Compare features, request pricing, and connect instantly with manufacturers — no registration required.