FluoSens Go (fluorescence measurement of the dyes HEX and Cy5)
For pricing, technical or any other questions please contact the supplier
- No registration required
- No markups, no fees
- Direct contact with supplier
-
Ships from:
Germany
-
Sold by:
Lumalytix powered by Dermagnostix GmbH -
On FindLight:
since 2025
Description
FluoSens Go is a confocal fluorescence detectors for the simultaneous measurement of two separate fluorescent dyes. The confocal optics allows contact-free measurements on surfaces and in liquids in the presence of ambient light. FluoSens Go is a plug-and-play detector equipped with stand-alone software for recording measurement results, and it can also be integrated into your device.
Our detectors set the benchmark in optical measurement technology, delivering
unmatched precision and sensitivity in both fluorescence and reflective
detection. Each detector is engineered to simultaneously detect two wavelength
combinations (i.e., two dyes) across the full spectrum from UV to IR (320 nm – 980
nm), with standard combinations including:
- Excitation 1: 470 nm / Detection 1: 520 nm (FAM)
- Excitation 2: 565 nm / Detection 2: 625 nm (ROX)
- Excitation 1: 520 nm / Detection 1: 570 nm (HEX)
- Excitation 2: 625 nm / Detection 2: 680 nm (Cy5)
- Excitation: 365 nm / Detection: 460 nm (UV fluorescence)
Excitation: 365 nm / Detection: 625 nm (Europium) Furthermore, the detectors can be customized on specific wavelengths, according to your needs. We also support our
customers with the integration of FluoSens Integrated into their devices.
FluoSens Go (fluorescence measurement of the dyes HEX and Cy5)
Specifications |
|
---|---|
Dynamic Range: | 0.2 – 800 nM |
Sampling Rate: | 100 samples/sec |
Excitation Wavelength Range: | 365 – 625 nm |
Detection Wavelength Range: | 460 – 680 nm |
Excitation 1 (e.g. Fluorescent Dye: HEX): | 520 nm |
Detection 1 (e.g. Fluorescent Dye: HEX): | 570 nm |
Excitation 2 (e.g. Fluorescent Dye: Cy5): | 625 nm |
Detection 2 (e.g. Fluorescent Dye: Cy5): | 680 nm |
Lower Limit Of Detection (LLOD) Detection 1: | HEX: 4 pM |
Lower Limit Of Detection (LLOD) Detection 2: | Cy5: 420 pM |
Electric Connection: | Micro-USB / M12 |
Dimensions: | 82 x 52 x 17.8 mm |
Features
High sensitivity, fast, precise, compact, customizable, flexible
Applications
- Fluorescence detection of liquids and solids
- Detection unit used in point-of-care devices/analyzers
- Fluorescence detection and monitoring of biochemical reactions
- Detection unit for microfluidics
- Inline measurement (production control in industrial applications)