TauTec - PicoStar UF- Ultrafast Picosecond Time-Gated ICCD Camera
For pricing, technical or any other questions please contact the supplier
- No registration required
- No markups, no fees
- Direct contact with supplier
-
Ships from:
United States
-
Sold by:
TauTec LLC -
On FindLight:
since 2023
Description
The PicoStar UF is an ICCD/CMOS camera consisting of a state-of-the-art picosecond time-gated image intensifier coupled to the CCD/CMOS camera via a high optical efficiency relay optics. In the ultra-fast time-gated mode, the image intensifier has a minimum gate width <65ps @ trigger rate <10kHz
TauTec - PicoStar UF- Ultrafast Picosecond Time-Gated ICCD Camera
Specifications |
|
---|---|
Sensor Type: | iCCD |
# Pixels (Width): | 1920 |
# Pixels (Height): | 1200 |
Pixel Size (Square): | 5.86 um |
Peak Quantum Efficiency: | 70 % |
Full Frame Rate: | 150 fps |
Bit Depth: | 12 bit |
Gate Width: | 50 ps |
Trigger Rate: | 10 kHz |
Spectral Response: | 200-900 nm |
Photocatode: | S20 or S25 |
Photocathode Size: | 18 mm |
Features
- Minimum Gate Width/exposure time: 50ps
- Maximum Gating Rate: 10kHz
- 18mm diameter photocathode, spectral response 200-900nm
Applications
- Picosecond Time-resolved Optical Imaging and Spectroscopy
- Fluorescence Lifetime Imaging Microscopy (FLIM/FRET)
- 3D-FLIM in conjunction with multifocal multiphoton microscopy
- Imaging through scattering media
- Diffuse optical tomography, optical breast imaging, photon migration
- Time-gated total internal reflection fluorescence microscopy
- Single molecule, Quantum Dot imaging and spectroscopy
- Dynamics of photophysical and photochemical processes
- Time-gated Raman spectroscopy & imaging: suppression of fluorescence
- Fluorescence quenching near silver/gold nanoparticles
- Pump-Probe imaging & spectroscopy
- Plasma kinetics/dynamics imaging and spectroscopy
- OLED characterization: electroluminescence kinetics and heterogeneity
- Dynamics of exciton, polariton and charge transport processes in semiconductors
- Ultrafast magnetic domain switching using time-resolved Kerr microscopy
- Gating and Ranging; LIDAR
- Underwater imaging through turbid media
Frequently Asked Questions
The minimum gate width/exposure time of the PicoStar UF camera is 50ps.
The maximum gating rate of the PicoStar UF camera is 10kHz.
The diameter of the photocathode in the PicoStar UF camera is 18mm.
Some applications of the PicoStar UF camera include picosecond time-resolved optical imaging and spectroscopy, fluorescence lifetime imaging microscopy (FLIM/FRET), and imaging through scattering media.
The PicoStar UF camera is controlled either directly via a front panel keypad or remotely via a USB interface.