ASOPS Engine Time-Domain Spectroscopy System
Description
Novanta ASOPS Engine
Novanta specializes in photonics solutions, offering cutting-edge components and sub-systems tailored for laser-based applications in diagnostic, analytical, micromachining, and fine material processing fields. Our powerful lasers, advanced beam steering, and intelligent sub-systems, coupled with sophisticated software and controls, deliver unparalleled precision and performance to meet the demanding requirements of our customers.
Laser Quantum, a part of Novanta, pioneers ASOPS technology, leading the market for nearly 15 years. The third-generation ASOPS technique offers the most precise and fastest time-domain spectroscopy available today, ensuring exceptional performance in various applications.
Key Benefits:
- Enables Two-Color Pump-Probe Experiments: Ideal for diverse research and analytical applications.
- High-Speed Data Acquisition: Capable of handling rapid data acquisition rates up to 20 kHz.
- Turn-Key Locking Electronics: Simplifies setup and ensures stable operation.
- Flexible Offset Frequencies: Offers offset frequencies between 4 µHz and 20 kHz for enhanced versatility.
Experience unparalleled precision and performance in optical spectroscopy and research with the Novanta ASOPS Engine, designed to meet the most demanding requirements of modern scientific and industrial applications.
ASOPS Engine Time-Domain Spectroscopy System
Specifications |
|
---|---|
Rep Rate: | 84-1000MHz |
Time Resolution: | 60 - 100 fs model dependent |
Time Delay Window: | 1 - 11.9 ns model dependent |
Features
Fast Acquisition Speed: Up to 20 kHz for rapid data acquisition.
Unprecedented Time-Resolution: Below 60 fs for 1 GHz lasers and below 100 fs for 84 MHz lasers, enabling precise measurements.
Dual Femtosecond Lasers: Master and slave lasers locked in a configuration with slight offset frequencies, facilitating automatic time-delay generation for pump-probe experiments.
Components Included:
- Femtosecond Lasers: Choose from 1 GHz or 84 MHz options, providing flexibility based on application requirements.
- TL-1000 ASOPS Unit: Ensures offset frequency stabilization for precise synchronization.
- Optical Trigger Unit: Facilitates triggering of laser pulses for accurate timing.
- High-Speed Balanced Optical Photoreceiver: Enables efficient detection of optical signals.
- Data Acquisition and Analysis: Supported by a personal computer housing the data acquisition card and HASSP-Scope software for comprehensive measurement and analysis.
Applications
The Novanta ASOPS Engine finds applications in various fields where high-speed, precise time-domain spectroscopy is crucial. Some of the key applications include:
- Material Characterization: Provides insights into the structural and chemical properties of materials, aiding in the development of advanced materials for electronics, photonics, and nanotechnology.
- Ultrafast Dynamics Studies: Allows researchers to investigate ultrafast processes such as photochemistry, photophysics, and molecular dynamics with unparalleled time-resolution.
- Optical Imaging: Enables high-speed imaging techniques such as pump-probe microscopy and fluorescence lifetime imaging, enhancing imaging capabilities in biological and materials science research.
- Spectroscopic Imaging: Supports spectroscopic imaging techniques for spatially-resolved chemical analysis, allowing researchers to map chemical composition with high precision.
- Laser Spectroscopy: Enhances laser spectroscopy experiments, enabling researchers to study complex molecular systems and chemical reactions in real time.
Overall, the Novanta ASOPS Engine offers versatile solutions for a wide range of scientific and industrial applications that require high-speed, precise time-domain spectroscopy capabilities.
For pricing, technical or any other questions please contact the supplier
- No registration required
- No markups, no fees
- Direct contact with supplier
-
Ships from:
United States
-
Sold by:
-
On FindLight:
since 2016
Frequently Asked Questions
The ASOPS Engine Time-Domain Spectroscopy System is a next-generation time-domain spectroscopy system that uses ASynchronous OPtical Sampling (ASOPS) technology for the most precise and fastest time-domain spectroscopy available on the market today.
The key features of the ASOPS Engine include extremely fast acquisition speed of up to 20 kHz, an unprecedented time-resolution of significantly below 60 fs* for 1 GHz lasers and below 100 fs for 84 MHz lasers respectively. This unique combination of high scan rates, long measurement windows and excellent time resolution is impossible with conventional time-domain spectrometers.
The ASOPS Engine is used for time-domain spectroscopy and enables two-colour pump-probe experiments.
The ASOPS Engine includes all components necessary for high-speed ASOPS time-domain spectroscopy: two femtosecond lasers, master and slave, in addition to the TL-1000 ASOPS electronic unit for stabilising the repetition rate of the slave laser with an offset to its master laser.
Laser Quantum offers a choice of either 1 GHz or 84 MHz femtosecond laser options.