Description

The Delta Optical Thin Film LVVISBP is a narrowband linear variable bandpass filter for the visible range. Its passband shifts continuously along the length of the filter, from about 394 nm to 718 nm over 47.8 mm (around 6.8 nm/mm). The bandwidth grows from about 3 nm FWHM in the blue to about 9 nm in the red, and out-of-band blocking is typically OD4–5 from 300 to 800 nm. Moving the filter across a beam, or imaging through it, gives a continuously selectable narrow band without gratings or a set of fixed filters. That makes it a good fit for compact spectrometers, hyperspectral imaging and tunable light sources.

LVVISBP Narrowband Linear Variable Bandpass Filter – Tunable 394–718 nm

Specifications

Filter Type: Bandpass
Tuning Range: 394 – 718 nm
Gradient Length: 47.8 mm
Average Dispersion: 6.8 nm/mm
Average Transmission: 20 – 88 %
Blocking (OD): 4
Bandwidth FWHM: 3–9 nm
Model: LVVISBP (LF102773)
Peak Transmission (Typical): ~20 % at 394 nm, ~48 % at 443 nm, ~64 % at 528 nm, ~75 % at 624 nm, ~88 % at 718 nm
Bandwidth FWHM (Typical): ~3 nm at 400 nm to ~9 nm at 700 nm
Out-Of-Band Blocking (Typical, 300–800nm): ~OD4–5
Measurement Conditions: 0.2 mm spot width, 1 nm spectral bandwidth
Manufacturer Part Number (MPN): LF102773
FindLight SKU: FL-24913

Got questions about specs? Use the inquiry form to ask.

Document icon Download Data Sheet Download icon

Features

  • Continuously tunable narrow passband from ~394 to 718 nm
  • 3–9 nm FWHM across the range
  • Typical OD4–5 blocking from 300 to 800 nm
  • Peak transmission up to ~88% in the red
  • ~6.8 nm/mm linear dispersion
  • Single-substrate design, no moving gratings

Applications

  • Compact and miniature spectrometers
  • Hyperspectral and multispectral imaging
  • Tunable monochromatic sources from broadband lamps or LEDs
  • Fluorescence excitation and emission selection
  • Colorimetry and spectral sensing

Export & Trade Information

ECCN: EAR99
HTS Code: 9001.90.9000
Estimated US Tariff: 10%

Importing, tariffs & codes (Quick Guide) →

Frequently Asked Questions

What does “narrowband” mean here?
The passband is about 3 nm FWHM at 400 nm and widens to about 9 nm at 700 nm.
How do I select a wavelength?
Translate the filter across the beam. The centre wavelength changes by about 6.8 nm per mm.
Why is transmission lower in the blue?
Narrow passbands in the blue are harder to coat. Peak T is ~20% near 394 nm and rises to ~88% at 718 nm.
How well does it block out-of-band light?
Measured blocking is typically OD4–5 between 300 and 800 nm.
How was it measured?
With a 0.2 mm spot and 1 nm spectral bandwidth. Larger beams will broaden the passband.