FILTER PRODUCTS

to
to
to
to
to
to

UV-VIS Optical Cells

Quartz Cuvette 50mm Large Capacity Reaction cell / quartz square cylinder for Ultraviolet transparent Optical pathlength: 50mm (Long path length) Wall thickness: 2mm Process: Melting and integrating process Material: Japanese quartz optical glass Light transmittance: >80% Applicable wavelength: 200-2500nm

Specifications

Window Material: Quartz
Wavelength Range: 200-2500nm
Width: 55 mm
Depth: 55 mm
Height: 55 mm
...
Data Sheet
The TrayCell is a fibre-optic ultra-micro cell designed for the UV/Vis analysis of DNA/RNA and proteins. The dimensions of the TrayCell are equivalent to a standard cuvette in order to work in most spectrophotometers.

Specifications

Window Material: Quartz SUPRASIL
Wavelength Range: 190-1100nm
Width: 12.5 mm
Depth: 12.5 mm
Height: 80 mm
...
Data Sheet
The TrayCell is a fibre-optic ultra-micro cell designed for the UV/Vis analysis of DNA/RNA and proteins. The dimensions of the TrayCell are equivalent to a standard cuvette in order to work in most spectrophotometers.

Specifications

Window Material: Quartz SUPRASIL
Wavelength Range: 190-1100nm
Width: 12.5 mm
Depth: 12.5 mm
Height: 64.5 mm
...
Data Sheet
Specvettes
Spectraline Inc
Low volume, precision cuvettes for transmission measurements, the SpecVette offers an economical alternative to quartz cuvettes. Short paths lengths: 250, 500 and 1000 m, only require a few micro liters of sample solution (12, 25 and 50 l). Nominal path lengths to +/- 10% – no parallax as found in molded cuvettes. Matched ...

Specifications

Window Material: Custom
Wavelength Range: 220-900nm
Width: --- mm
Depth: -- mm
Height: -- mm
...
Data Sheet
SpecVette Starter Pack
Spectraline Inc
Low volume, precision cuvettes for transmission measurements, the SpecVette offers an economical alternative to quartz cuvettes. Short paths lengths: 250, 500 and 1000 m, only require a few micro liters of sample solution (12, 25 and 50 l). Nominal path lengths to +/- 10% – no parallax as found in molded cuvettes. Matched ...

Specifications

Window Material: Custom
Wavelength Range: 220-900nm
Width: -- mm
Depth: -- mm
Height: -- mm
...
Data Sheet
Fluorescence Cuvettes
Spectraline Inc
Micro-volume cuvette great for fluorescence detection. The pipettor format allows for static fluorescence measurements using a standard fluorimeter.

Specifications

Window Material: Custom
Wavelength Range: -----nm
Width: 4.3 mm
Depth: 1 mm
Height: 4.7 mm
...
Data Sheet
Spectrophotometer Cells Flowcell Type 71 Maximum Aperture
Starna Cells Inc
Flow cells are used for measuring samples with continuous flow as in chromatography or on-line production monitoring such as tablet dissolution. They may also be used in sipper systems where individual samples are aspirated into and out of the cell either by a syringe or pumping system. A wide variety of flow cell designs are ...

Specifications

Window Material: Not Specified
Wavelength Range: 170-2700nm
Width: 12.5 mm
Depth: 12.5 mm
Height: 48 mm
...
Data Sheet
Short Pathlength Cylindrical Spectrophotometer Cells
Starna Cells Inc
Cylindrical cells are used where a spectrophotometer has a larger, circular light beam and sample volume is not a consideration. Starna offers several configurations with pathlengths from 0.01 to 100mm. Check the pages listed below for references on each of the designs available.

Specifications

Window Material: Not Specified
Wavelength Range: 170-2700nm
Width: 22 mm
Depth: 22.5 mm
Height: -- mm
...
Data Sheet
Standard Rectangular Spectrophotometer Cells
Starna Cells Inc
Rectangular Spectrophotometer CellsRectangular cells are used for most UV/VIS routine analysis. By far the most common type of cell, they have two windows clear and conform to international standard dimension. The 10mm pathlength size should fit most instruments that use rectangular cells. Available pathlengths are from 1mm to 100mm. ...

Specifications

Window Material: Not Specified
Wavelength Range: 334-2500nm
Width: 12.5 mm
Depth: 3.5 mm
Height: 45 mm
...
Data Sheet
Standard Fluorometer Cell 10mm Style A 3.5mL
World Precision Instruments
WPI’s glass and synthetic quartz cuvettes are ideal for UV/VIS/NIR absorbance or fluorescence experiments. Synthetic quartz can be used in deep UV applications and is recommended for fluorescent applications, as it does not exhibit background fluorescence. Quartz cuvettes (absorbance, fluorescence and flow) are shipped individually ...

Specifications

Window Material: N-BK7, Quartz, Quartz SUPRASIL
Wavelength Range: 200-2500nm
Width: 10 mm
Depth: 10 mm
Height: 30 mm
...
Data Sheet
Cylindrical Quartz Cuvette 100mm Path Style G
World Precision Instruments
WPI’s glass and synthetic quartz cuvettes are ideal for UV/VIS/NIR absorbance or fluorescence experiments. Synthetic quartz can be used in deep UV applications and is recommended for fluorescent applications, as it does not exhibit background fluorescence. Quartz cuvettes (absorbance, fluorescence and flow) are shipped individually ...

Specifications

Window Material: Quartz, Quartz SUPRASIL
Wavelength Range: 200-2500nm
Width: 22 mm
Depth: 22 mm
Height: 102.5 mm
...
Data Sheet
Type 1 UV Quartz Cell with Closed Screw Cap
Reflex Analytical Corporation
Standard cell with closed screw cap. Satin finish on two sides. Cell dimensions 45mm height x 12.50mm wide with screw cap, overall height 56mm. REFLEX Analytical manufactures many popular types of UV-VIS-NIR spectrophotometer cells. Samples to be measured for absorbance or transmission are retained in the cells for use with all ...

Specifications

Window Material: Quartz SUPRASIL, Quartz
Wavelength Range: 190-2500nm
Width: 12.5 mm
Depth: 8 mm
Height: 56 mm
...
Data Sheet
Type 1 UV Quartz Cell with Graded Seal
Reflex Analytical Corporation
Standard cell with a graded seal. Satin finish on two sides. Cell dimensions 45mm height x 12.50mm wide with 8mm outside diameter graded seal, overall height 120mm. REFLEX Analytical manufactures many popular types of UV-VIS-NIR spectrophotometer cells. Samples to be measured for absorbance or transmission are retained in the cells ...

Specifications

Window Material: Quartz SUPRASIL, Quartz
Wavelength Range: 190-2500nm
Width: 45 mm
Depth: 8 mm
Height: 120 mm
...
Data Sheet
Type 1 UV Quartz Cells
Reflex Analytical Corporation
Standard cell with fitted cover. Satin finish on two sides. Dimensions 45mm height x 12.50mm wide. REFLEX Analytical manufactures many popular types of UV-VIS-NIR spectrophotometer cells. Samples to be measured for absorbance or transmission are retained in the cells for use with all common spectrophotometers. Our cells comply with ...

Specifications

Window Material: Quartz
Wavelength Range: 190-2500nm
Width: 12.5 mm
Depth: -- mm
Height: 45 mm
...
Data Sheet
On FindLight marketplace you will find 14 different UV-VIS Optical Cells from suppliers around the world. With just a few clicks you can compare different UV-VIS Optical Cells and get accurate price quotes based on your needs and quantity required. Note that some wholesale suppliers may offer discounts for large quantities. From any product page you can directly contact any vendor within seconds.