FILTER PRODUCTS

Select a category above to apply technical filters

Page 2 - Material Analysis and Forensics

The TrayCell is a fibre-optic ultra-micro cell designed for the UV/Vis analysis of DNA/RNA and proteins. The dimensions of the TrayCell are equivalent to a standard cuvette in order to work in most spectrophotometers.

Specifications

Window Material: Quartz SUPRASIL
Wavelength Range: 190-1100nm
Width: 12.5 mm
Depth: 12.5 mm
Height: 64.5 mm
...
Data Sheet
Hellma Analytics produces a wide range of cuvettes for use in spectroscopy and cytometry with optical path lengths spanning 0.01 mm to 100 mm and above. Thanks to their stability, maximum precision and reliability when used for absorbance and fluorescence measurements, Hellma cuvettes work exceptionally well in a ...

Specifications

Window Material: Special optical glass (OS)
Wavelength Range: 320-2500nm
Width: 12.5 mm
Depth: 12.5 mm
Height: 45 mm
...
Data Sheet
Hellma Analytics produces a wide range of cuvettes for use in spectroscopy and cytometry with optical path lengths spanning 0.01 mm to 100 mm and above. Thanks to their stability, maximum precision and reliability when used for absorbance and fluorescence measurements, Hellma cuvettes work exceptionally well in a ...

Specifications

Window Material: Quartz glass high performance (QS)
Wavelength Range: 200-2500nm
Width: 12.5 mm
Depth: -- mm
Height: 45 mm
...
Data Sheet
Hellma Analytics produces a wide range of cuvettes for use in spectroscopy and cytometry with optical path lengths spanning 0.01 mm to 100 mm and above. Thanks to their stability, maximum precision and reliability when used for absorbance and fluorescence measurements, Hellma cuvettes work exceptionally well in a ...

Specifications

Window Material: Quartz glass high performance (QS)
Wavelength Range: 200-2500nm
Width: 12.5 mm
Depth: 12.5 mm
Height: 45 mm
...
Data Sheet
Rosemount CT4400 Continuous Gas Analyzer
Cascade Technologies
Emerson\'s Rosemount CT4400 is the world\'s first purpose-built hybrid Quantum Cascade Laser (QCL) and Tunable Diode Laser (TDL) process gas analyzer designed to enhance performance and reduce costs specifically in NOx measurement and continuous emissions monitoring applications.   Optimized for cold/dry applications ...

Specifications

Type Of Compound: Hydrogen, CO (Carbon Monoxide), CO2 (Carbon Dioxide), NOx
Detection Technology: Not Specified
Minimum Detectivity: 0.02 ppt (parts per trillion)
Data Sheet
Reflected UV Imaging System is a simple, non-destructive and extremely effective technique that significantly aids in the visualization of latent fingerprints or hidden evidence without any treatment, on various smooth or non-porous surfaces. The system comes and works with specialist DSLR camera (UV-IR sensitive camera) for ...

Specifications

IR LED: 850nm, 940nm / 5W (handheld flashlights)
Model No.: OR-GZP1000
Battery Voltage: DC 12.6 V
Battery Capacity: 6000 mAh
UV LED: UV-365nm / 36W
...
Data Sheet
LocateDNA offers a complete solution to search, reveal, and collect DNA evidence including Touch DNA, body fluids, and other traces using state of the art forensic search and detection tools. High-efficiency location of Touch DNA (epithelial cells) collection areas, and sampling of Touch DNA in a specific range; reveals and enhances ...

Specifications

Illumination: UV-Blue-Laser
Interface: Smartphone IOS
Data Sheet
42iQ High Level NO-NO2-NOx Analyzer
Thermo Fisher Scientific
The 42iQHL analyzer is a single chamber, single photo multiplier tube design that cycles between the NO and NOx modes. This instrument has independent outputs for NO, NO2 and NOx and each can be calibrated separately.  Dual range and auto range are standard features as well. If required, the instrument can ...

Specifications

Type Of Compound: Oxygen, NOx
Detection Technology: Custom
Minimum Detectivity: 50000 ppt (parts per trillion)
Response Time: 2.5 sec.
Sample Flow Rate: 25 cc/min
...
Data Sheet
In crime scene investigation, fast and accurate detection of possible forensic traces is of vital important. Forensic Alternate Light Sources(ALS) have been used for detection of biological evidences, which can be detected due to their nature characteristic, such as light asorption (blood) or flurescence effect (semen, saliva, urine, ...
Data Sheet
Crime scene footwear impressions are most valuable as forensic evidence, in crime of burgalry, assault, robberies, repe, homicide and other crimes, where proof of an individual’s presence is incriminating. They provide valuable information to the scene of crime officer and investigators, including information concerning the ...
Data Sheet
NEW Forensic Light with THREE frequently-used wavelengths---OR-GSS600: * Three wavelengths with high power: UV 365nm/10Watt, Blue 450nm/10Watt, * White 6500K/10Watt.* All three wavelengths in one handheld unit (all-in-one).* Quartz Optical Lens designed for best UV light utility.* Rechargeable Li-ion 18650 batteries.* Lighting ...
Data Sheet
FEATURES: A most multifunctional tool to forensic examiners at crime scene and in the forensic laboratory. Providing essential light sources required to reveal/enhance contrast evidence, including general search, body fluids(semen, saliva, etc.); fingerprints; traces of physical evidence(hairs, fibres, etc.); footwear/tire ...
Data Sheet
Touch DNA, also know as Trace DNA, is a forensic method for analysing DNA left at the scene of a crime, it only requires very small samples, for example from the skin cells left on an object after it has been touched or casually handled, or from footprints. Touch DNA analysis only requires several cells from the outermost layer ...
Data Sheet
Capillaries plate arrays consist of millions of precision capillary hollows together in a glass substrate, it equivalent to there are millions of individual channels/holes in the glass substrate.

Specifications

Compound Analysis: Ethanol, Methanol, Alcohols (unspecified), Acids (unspecified), Esters (unspecified)
Data Sheet
HORIBA has been selling our XGT-WR series of EDXRF analyzers worldwide for many years to provide screening measurements of samples containing hazardous elements such as Pb, Cd, Cr, Hg, Br for RoHS, ELV, and Cl for halogen-free applications. XGT systems are used daily throughout the world. HORIBA has now developed the MESA-50 EDXRF ...

Specifications

Element: Carbon, Sulfur, Oxygen, Ozone, Nitrogen, Hydrogen, Helium
Data Sheet
EMGA-921 is a hydrogen elemental analyzer with high accuracy and repeatability suited to advanced R&D as well as quality control in the markets of steel, new materials, catalysts and many others. This is a new generation model optimized to fit the user’s needs.

Specifications

Element: Hydrogen
Data Sheet
The Mini- CrimeScope® has been among the most powerful Forensic Light Sources for some time. Now, utilizing a higher Intensity 400W bulb, manufactured specifically for use in the Mini-CrimeScope®, as well as new high throughput, high durability filters, the MCS-400 stands alone as the most ...
Data Sheet
Reflective Ultra Violet Imaging Systems are an integral part of the crime scene investigator‘s search for evidence. By enhancing the observation and collection of evidence including latent prints on smooth non-porous surfaces, bites, bruises, blood detection with Bluestar®, and shoe ...
Data Sheet
The HandScope® Xenon is a new Forensic Light Source that combines the versatility of multiple wavelengths with the convenience of battery power. It features more intensity than other battery powered alternate light sources and a larger, more highly defined, focusable spot size. This ...
Data Sheet
The new EMIA-Pro Carbon/Sulfur analyzer series has been developed based on HORIBA’ s abundant NDIR technologies and the wealth of experience acquired from our successful EMIA series. This “made in Japan” product offers four unique features to allow anyone to become a professional analyst. 

Specifications

Element: Carbon, Sulfur
Data Sheet
EMGA-920 is a simultaneous oxygen/nitrogen elemental analyzer with high accuracy and repeatability suited to advanced R&D as well as quality control in the markets of steel, new materials, catalysts and many others. This is a new generation model optimized to fit the user’s needs.

Specifications

Element: Oxygen, Nitrogen
Data Sheet
The CS-16-500W-15F is ideal for those departments that prefer Xenon Lamps to Metal Halide Lamps because of the extra Infrared output for forged documents. While designed to fit comfortably in the lab, the CrimeScope® is small enough to be taken to the crime scene making it an exceptional dual use unit. The CS-16-500W-15F covers ...
Data Sheet
Specvettes
Spectraline Inc
Low volume, precision cuvettes for transmission measurements, the SpecVette offers an economical alternative to quartz cuvettes. Short paths lengths: 250, 500 and 1000 m, only require a few micro liters of sample solution (12, 25 and 50 l). Nominal path lengths to +/- 10% – no parallax as found in molded cuvettes. Matched ...

Specifications

Window Material: Custom
Wavelength Range: 220-900nm
Width: --- mm
Depth: -- mm
Height: -- mm
...
Data Sheet
SpecVette Starter Pack
Spectraline Inc
Low volume, precision cuvettes for transmission measurements, the SpecVette offers an economical alternative to quartz cuvettes. Short paths lengths: 250, 500 and 1000 m, only require a few micro liters of sample solution (12, 25 and 50 l). Nominal path lengths to +/- 10% – no parallax as found in molded cuvettes. Matched ...

Specifications

Window Material: Custom
Wavelength Range: 220-900nm
Width: -- mm
Depth: -- mm
Height: -- mm
...
Data Sheet
Fluorescence Cuvettes
Spectraline Inc
Micro-volume cuvette great for fluorescence detection. The pipettor format allows for static fluorescence measurements using a standard fluorimeter.

Specifications

Window Material: Custom
Wavelength Range: -----nm
Width: 4.3 mm
Depth: 1 mm
Height: 4.7 mm
...
Data Sheet