AVI-600S Platform
Herzan LLC
The AVI-600 platforms provide industry-leading active vibration isolation performance (starting at 0.5 Hz) for the precision research industry’s largest instruments (e.g. TEMs). The AVI-600 platforms help users achieve more from their instruments by removing disruptive low frequency vibration noise from affecting the quality of ...

Specifications

Height Of Vibration Isolation System: -- mm
Vertical Movement Range: -- mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 200 Hz
Horizontal Resonant Frequency: 200 Hz
...
Data Sheet
AVI-400S Platfotm
Herzan LLC
The AVI-400 platforms provide industry-leading active vibration isolation performance (starting at 0.5 Hz) for electron microscopes and similarly large research instruments. The AVI-400 platforms help users achieve more from their microscopes by removing disruptive low frequency vibration noise from affecting their measurements. The ...

Specifications

Height Of Vibration Isolation System: -- mm
Vertical Movement Range: -- mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 200 Hz
Horizontal Resonant Frequency: 200 Hz
...
Data Sheet
AVI-200S Platform
Herzan LLC
The AVI-200 platforms help users achieve more from their research by removing disruptive low frequency vibrations from affecting their measurements. The AVI-200 platforms are field-tested solutions, leading the industry in terms of low-frequency active vibration isolation performance (starting at 0.5 Hz) for compact microscopes ...

Specifications

Height Of Vibration Isolation System: -- mm
Vertical Movement Range: -- mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 200 Hz
Horizontal Resonant Frequency: 200 Hz
...
Data Sheet
The Compact Tabletop (CT-2) uses Minus K\'s patented breakthrough technology allowing for the best performance on the market in just 2.7 inch tall isolation platform. This completely passive mechanical isolator offers 10-100 times better performance than a full size air table. It does this without any air or electricity! This ...

Specifications

Height Of Vibration Isolation System: 68.6 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 1.5 Hz
...
Data Sheet
VERE Over Table Shelf Assemblies
Vere
The Over Table Shelf Assembly is ideal for opitimizing your otherwise wasted laboratory space.  The 24” deep recessed shelf has a 2” grid of 1/4-20 holes on the underside for attachment of hanging shelves or a lighting system.  Includes a power strip with 3-prong 110vac electrical outlets.  The leveling feet are ...

Specifications

Height Of Vibration Isolation System: 1625.6 mm
Vertical Movement Range: -- mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: -- Hz
Horizontal Resonant Frequency: -- Hz
...
Data Sheet
VERE Vibration Isolation Legs
Vere
VERE Vibration Isolation Legs.

Specifications

Height Of Vibration Isolation System: 750 mm
Vertical Movement Range: 750 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 2 Hz
Horizontal Resonant Frequency: 2 Hz
...
Data Sheet
VERE Vibration Isolation Workstation Stands
Vere
Our sturdy support stands are constructed of 3\" square steel  tube legs and 2\" square steel cross bars. The standard support stand has  leveling feet that are height adjustable +/- 1 - 2 inches. Locking casters or  leveling casters are optional. For applications requiring a passive isolation system for use  ...

Specifications

Height Of Vibration Isolation System: 76.2 mm
Vertical Movement Range: 50 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: -- Hz
Horizontal Resonant Frequency: -- Hz
...
Data Sheet
VERE Vibration Isolation Table Stands
Vere
There are a variety of approaches to vibration isolators for  optical tables. All of these come down to having to isolate in the horizontal  direction and vertical direction. Piston isolators have the limitation that the  isolation is only in the piston direction, normally the vertical axis. As a  result, an ...

Specifications

Height Of Vibration Isolation System: -- mm
Vertical Movement Range: -- mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 2 Hz
Horizontal Resonant Frequency: 2 Hz
...
Data Sheet
VERE Vibration Isolation Platforms And Systems
Vere
VIPS series of vibration isolation platforms are fully assembled isolated platforms for microscopes, interferometers and other vibration sensitive equipment. Just set on a flat surface, connect one air-line, put your instrument on top and in under 5 minutes, you are isolated. Top surface has no holes. No assembly, no ...

Specifications

Height Of Vibration Isolation System: -- mm
Vertical Movement Range: -- mm
Precision Of Automatic Level Control: <= +/-0.1mm mm
Vertical Resonant Frequency: 2.5 Hz
Horizontal Resonant Frequency: 2.5 Hz
...
Data Sheet
Low frequency vibration isolator for weight loads from 15 to 130 lbs. and 1/2 Hz performance vertical and horizontal. Minus K’s new LC-4 is an ultra compact, low-frequency negative-stiffness isolator. It comes in two configurations, our low horizontal frequency performance of 1.5 Hz or our ultra low horizontal frequency ...

Specifications

Height Of Vibration Isolation System: 216 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
Low frequency vibration isolator for weight loads from 50 to 1050 lbs. and 1/2 Hz performance vertical and horizontal. The new CM-1 is a compact high capacity, low-frequency negative-stiffness isolator. As with all Minus K isolators, they are completely passive and use no air or electricity. The isolators can be combined into multi ...

Specifications

Height Of Vibration Isolation System: 216 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
The MK52 Vibration Control Workstation with more ergonomic comfort is designed specifically for ultra-low natural frequency applications. The system utilizes Minus K negative stiffness vibration isolators in order to provide a compact, passive Vibration Isolation Workstation with ultra-low natural frequencies, higher internal ...

Specifications

Height Of Vibration Isolation System: 788 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
The MK26 Vibration Control Workstation with more ergonomic comfort is designed specifically for ultra-low natural frequency applications. The system utilizes Minus K negative stiffness vibration isolators in order to provide a compact, passive Vibration Isolation Workstation with ultra-low natural frequencies, higher internal ...

Specifications

Height Of Vibration Isolation System: 788 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
Minus K isolators, they are completely passive and require NO AIR or ELECTRICITY. There are no computers, compressors or air lines needed or that can breakdown. The WS-4 Compact Vibration Isolation Table offers better performance than a full size air table. The table come in several capacity ranges to match your vibration-sensitive ...

Specifications

Height Of Vibration Isolation System: 838 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
Minus K isolators, they are completely passive and require NO AIR or ELECTRICITY. There are no computers, compressors or air lines needed or that can breakdown. The BM-10 bench top platform offers 10-100 times better performance than a full size air table in a package only 4.6 inches tall and 12 inches wide and deep. The BM-10 is ...

Specifications

Height Of Vibration Isolation System: 115 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 1.5 Hz
...
Data Sheet
Minus K isolators, they are completely passive and require NO AIR or ELECTRICITY. There are no computers, compressors or air lines needed or that can breakdown. The BM-8 bench top platform offers 10-100 times better performance than a full size air table in a package only 4.6 inches tall. This is the thinnest, most portable, and most ...

Specifications

Height Of Vibration Isolation System: 115 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 1.5 Hz
...
Data Sheet
Minus K isolators, they are completely passive and require NO AIR or ELECTRICITY. There are no computers, compressors or air lines needed or that can breakdown. The BM-4 bench top platform offers better performance than a full size air table. The isolators come in several capacity ranges to match your vibration-sensitive ...

Specifications

Height Of Vibration Isolation System: 216 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
Minus K isolators, they are completely passive and require NO AIR or ELECTRICITY. There are no computers, compressors or air lines needed or that can breakdown. The BM-1 bench top platform offers better performance than a full size air table. The isolators come in several capacity ranges to match your vibration-sensitive ...

Specifications

Height Of Vibration Isolation System: 216 mm
Vertical Movement Range: 2.5 mm
Precision Of Automatic Level Control: Not Specified mm
Vertical Resonant Frequency: 0.5 Hz
Horizontal Resonant Frequency: 0.5 Hz
...
Data Sheet
There are 18 different Vibration Isolation from suppliers and manufacturers listed in this category. In just a few clicks you can compare different Vibration Isolation with each other and get an accurate quote based on your needs and specifications. Please note that the prices of Vibration Isolation vary significantly for different products based on various factors including technical parameters, features, brand name, etc. Please contact suppliers directly to inquire about the details and accurate pricing information for any product model. Simply navigate to the product page of interest and use the orange button to directly reach out to the respective supplier with one click.

Did You know?

Vibration isolation systems are built to suppress the propagation of mechanical waves among different parts of equipment. Two approaches are developed to achieve this goal. The first one is passive isolation. It makes use of materials and structures that absorb mechanical waves, and some commonly seen passive isolation components are pneumatic isolators, springs, and pads/sheets made of flexible materials such as elastomers, rubber, cork, dense foam and laminate materials. The second method is active isolation. It embeds the mechanical system with a feedback circuit, which can sense the vibration signals and generate stronger counteracting forces. Active isolation systems are able to monitor vibrations with much higher precision, and today they are utilized where structures smaller than a micrometer have to be produced or measured.