FILTER PRODUCTS

Select a category above to apply technical filters

Page 2 - Optical Metrology Equipment

Single Wavelength Polarimeter ADP450 With Temperature Control
Bellingham + Stenley, a Xylem brand
Capable of measuring up to 3.0 OD at 589nm over a maximum tube length of 200mm, ADP400 Series polarimeters offer three decimal place precision to an accuracy of ±0.01 °Angular, making them ideal for general purpose use in  food, flavors, fragrance, pharmaceutical and chemical industries as well as within academia and ...

Specifications

Wavelength Coverage: 1-1nm
Sampling Rate: -- Samples/Sec
Measured Parameters: Degree of Polarization
Humidity Range: <90% RH (non condensing)
Power: Instrument: 24 V DC, ±5%, <2A External PSU: 100-240V, 50-60Hz (supplied)
...
Data Sheet
Single Wavelength Polarimeter ADP430
Bellingham + Stenley, a Xylem brand
Capable of measuring up to 3.0 OD at 589nm over a maximum tube length of 200mm, ADP400 Series polarimeters offer three decimal place precision to an accuracy of ±0.01 °Angular, making them ideal for general purpose use in  food, flavours, fragrance, pharmaceutical and chemical industries as well as within academia ...

Specifications

Wavelength Coverage: 1-1nm
Sampling Rate: -- Samples/Sec
Measured Parameters: Degree of Polarization
Humidity Range: <90% RH (non condensing)
Power: Instrument: 24 V DC, ±5%, <2A External PSU: 100-240V, 50-60Hz (supplied)
...
Data Sheet
Polarimeter ADP610 with 589nm Wavelength and Peltier Temperature Control
Bellingham + Stenley, a Xylem brand
Available as single, dual and multiple wavelength derivatives covering the visible spectrum, the ADP600 Series also features measurement in the highly sensitive ultra-violet region.     This capability makes the instrument particularly suited for use by scientists wishing to measure chiral compounds and ...

Specifications

Wavelength Coverage: 589-589nm
Sampling Rate: -- Samples/Sec
Measured Parameters: Degree of Polarization, Other
Power Supply: 100-250V~, 50-60 Hz. <6A.
Interfaces: 4 x USB, 1 x Ethernet, 1 x RS232
...
Data Sheet
FBG Displacement Sensor DST-01 is used for long-term measurement of structural beams and large buildings or other concrete, steel structures, building settlements, displacements and landslides. The sensor is installed by pulling rope, which can accurately and quickly measure the beam settlement, the displacement and deformation of ...

Specifications

Measurement Range: 10-150mm
Measurement Resolution: 0.05 %
Center Wavelength: 1460 ~ 1610 nm
Measurement Accuracy: 0.5 % F.S.
Temperature Compensation: Built-in
...
Data Sheet
Embedded FBG strain sensor ES-01&EST-01 is specially used for the internal strain measurement of concrete, reinforced concrete or plastic materials, so as to observe the change of internal stress of the structure for a long time, conduct state analysis, and achieve the purpose of warning and object health status diagnosis. The ...

Specifications

Strain Sensitivity: 1.2 pm/με
Gage Length: 50 mm
Operating Temperature Range: -20-80deg C
Strain Limits: -1500-1500με
Center Wavelength: 1460 ~ 1610 nm
...
Data Sheet
Surface mounted FBG strain sensor MS-01/MST-01 can meet the strain measurement needs of various occasions, and can be installed in different monitoring positions such as concrete surfaces or steel surfaces. Mainly used to measure the strain of steel structures and concrete surfaces. The external strain transmits the strain to ...

Specifications

Strain Sensitivity: 1.2 pm/με
Gage Length: 71 mm
Operating Temperature Range: -20-80deg C
Strain Limits: -1500-1500με
Center Wavelength: 1460 ~ 1610 nm
...
Data Sheet
ContourX-500 3D Optical Profilometer
Bruker Nano Surfaces
The ContourX-500 Optical Profilometer is the world’s most comprehensive automated benchtop system for fast, non-contact 3D surface metrology. The gage-capable ContourX-500 boasts unmatched Z-axis resolution and accuracy, and provides all of the industry-recognized advantages of Bruker’s white light interferometry (WLI) floor-standing ...

Specifications

Light Source Type: CW LED, Modulated LED
Light Source Wavelength: -- nm
Sample Reflectivity: 0.05-100%
Vertical Range: 10000000 nm
RMS Repeatability: <0.01 nm
...
Data Sheet
ContourX-200 3D Optical Profilometer
Bruker Nano Surfaces
The ContourX-200 Optical Profilometer provides the perfect blend of advanced characterization, customizable options, and ease of use for best-in-class fast, accurate, and repeatable non-contact 3D surface metrology. The gage-capable, small footprint system offers uncompromised 2D/3D high-resolution measurement capabilities using a ...

Specifications

Light Source Type: CW LED, Modulated LED
Light Source Wavelength: -- nm
Sample Reflectivity: 0.05-100%
Vertical Range: 10000000 nm
RMS Repeatability: <0.01 nm
...
Data Sheet
DD309CS High Definition Video Micrometer - Protractor
Colorado Video Inc
The Video Caliper superimposes two vertical, horizontal, or diagonal, cursor lines, or two cursor points onto the video display. The user can adjust the position and rotation of these cursors by means of front panel controls. In most modes, one control sets the distance or angle between the cursors by moving one cursor only. The ...
Data Sheet
TD309C High Definition Video Micrometer - Protractor
Colorado Video Inc
The Video Caliper superimposes two vertical, horizontal, or diagonal, cursor lines, or two cursor points onto the video display. The user can adjust the position and rotation of these cursors by means of front panel controls. In most modes, one control sets the distance or angle between the cursors by moving one cursor only. The ...
Data Sheet
TD309CS High Definition Video Micrometer - Protractor
Colorado Video Inc
The Video Caliper superimposes two vertical, horizontal, or diagonal, cursor lines, or two cursor points onto the video display. The user can adjust the position and rotation of these cursors by means of front panel controls. In most modes, one control sets the distance or angle between the cursors by moving one cursor only. The ...
Data Sheet
CEO-2D-AD Angular Dispersion
CE Optics Ltd
Once a laser beam suffers from angular dispersion, its spectral components propagate into different directions. Hence, in the focal plane of an objective lens, the focal spot will be enlarged and distorted compared to an angular dispersion-free beam of the same size. The shape of the intensity distribution will be uniquely ...
Data Sheet
HPB- 75 Button Probe
Capacitec Inc
Capacitec’s HPB thin “side-looking” button probes are designed to measure displacement and part dimensional changes in tight or hidden access locations looking at an earth grounded target. The Button Series probes are particularly well suited for placement in very small, down to 0.025 in  (0.65mm), locations ...

Specifications

Measurement Range: 1.27-1.91mm
Measurement Resolution: -- %
Data Sheet
HPB- 40 Button Probe
Capacitec Inc
Capacitec’s HPB thin “side-looking” button probes are designed to measure displacement and part dimensional changes in tight or hidden access locations looking at an earth grounded target. The Button Series probes are particularly well suited for placement in very small, down to 0.025 in  (0.65mm), locations ...

Specifications

Measurement Range: 0.51-1.02mm
Measurement Resolution: -- %
Data Sheet
Conoscopic Scatterometer
Eckhardt Optics LLC
Eckhardt Optics designs and manufactures a line of scatterometers based on our conoscopes. To turn a conoscope into a scatterometer, we add light sources for transmissive measurements (BTDF) or reflective measurements (BRDF) and appropriate analysis software. These scatterometers can be customized to match your measurement requirements.

Specifications

Wavelength: 405-650nm
Resolution: 0.13 degrees
Accuracy: 5 %
Dynamic Range: 8-10bits
Data Sheet
Model 590 Optical Monitor
Dyn-Optics
Optical Monitoring provides the highest accuracy needed for today’s precision thin film coatings. Crystal monitors, by design, only measure the mass of a coating layer and cannot detect changes in the layer density caused by a variations in one of the many process variables. If not caught, a change in layer density results in a ...

Specifications

Diameter Range: 1-1mm
Resolution: -- um
Accuracy: -- um
Repeatability: -- um
Data Sheet
DAFFI MT DIGITAL AUTOMATED FIBER AND FERRULE INTERFEROMETER
Data-Pixel
Data-Pixel has developed a cost effective interferometer line for high volumes production without compromising accuracy or performance. Based on our extensive interferometer manufacturing experience we designed the DAFFI MT to be robust, fast and accurate in order to meet all manufacturing or laboratory environments. With the ...

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Data Sheet
DAISI MT FP AUTOMATED INTERFEROMETER
Data-Pixel
The Daisi MT FP combines the Daisi MT-V3 with the new Floating Pastille fixture technology from DATA-PIXEL (patent pending). This major technological breakthrough for multi-fiber connector fixtures is perfectly suited for highly accurate X/Y endface angle measurements. With the Floating Pastille fixtures, measurement ...

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Not Specified
RMS Precision: Not Specified
Data Sheet
DAISI-V3 DIGITAL AUTOMATED INTERFEROMETER
Data-Pixel
The ultimate production interferometer for measuring end-face geometry on single-fiber connectors, equipped with a revolutionary «no-exterior-moving-parts» mechanical design.The unit combines a x400 microscope and an interferometer in order to control connectors after polishing in a very short time.With the Blink ...

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Data Sheet
Vacuum Hood Inspection System
Dantec Dynamics A/S
The Q-810 is a rugged, lightweight Shearography vacuum hood for in-field use, especially configured for large area NDT inspections with high inspection rates of 300 mm x 200 mm every 10 seconds.

Specifications

Inspection Area: 600 cm^2
Data Sheet
FlawScout Sensor
Dantec Dynamics A/S
The FlawScout is a laser shearography non-destructive testing (NDT) sensor for applications in quality control, academic research or NDT training. Yielding sub-micrometer displacement resolution, the sensor delivers accurate and reliable measurement results through clear and sharp phase-map imaging. The sensor can be configured with ...

Specifications

Inspection Area: -- cm^2
Data Sheet
FlawExplorer NDT
Dantec Dynamics A/S
The FlawExplorer is a portable, compact, and robust Laser Shearography inspection system for Non-Destructive Testing (NDT) and Quality Control applications for composites and metallic materials with inspection areas from 10 cm2 up to ~2 m2 (~20 ft2) in one shot.

Specifications

Inspection Area: 10 cm^2
Data Sheet
Strain Gauge SG-01
FBGS International NV
The Strain Gage SG-01 is the fiber optic equivalent of an electrical strain gage. The Strain Gage SG-01 can be mounted directly on the surface of a structure by means of an adhesive. In this way, the fiber sensor makes direct contact with the surface and therefore accurately measures the strain at the surface. Supply of the strain ...

Specifications

Strain Sensitivity: - pm/με
Gage Length: 8 mm
Operating Temperature Range: -50-130deg C
Strain Limits: -5000-5000με
Data Sheet
Strain Gauge Chain SGC-01
FBGS International NV
The Strain Gauge Chain SGC-01 is the fiber optic equivalent of several electrical strain gauges, as the chain can be configured to customer needs. In this way an entire strain distribution can be monitored using just one fiber. The Strain Gauge Chain SGC-01 is a spliceless chain of several fiber optic Strain Gauges in series. These ...

Specifications

Strain Sensitivity: - pm/με
Gage Length: 8 mm
Operating Temperature Range: -50-130deg C
Strain Limits: -5000-5000με
Data Sheet
Strain Gauge Installation Kit SGK-01
FBGS International NV
The Strain Gauge Kit is designed for use on-site or in the lab and contains all the parts required to install fiber optic strain gauges. Includes materials for preparation of the measurement point, the strain gauges themselves, application tools & accessories, as well as means to clean, protect and compensate the applied gauges ...

Specifications

Strain Sensitivity: - pm/με
Gage Length: - mm
Operating Temperature Range: -45-90deg C
Strain Limits: -5000-5000με
Data Sheet