Model 358 UV Light & Intensity Energy Meters For High Intensity Steppers
OAI
This instrument is designed for use with the ASML High Intensity, Canon, Nikon, and Ultratech High Intensity Wafer Steppers. The microprocessor based Model 358 UV Light Intensity & Energy Meter performs measurement, storage and recall of nine series of readings. Reads intensity, energy, and time (4000 mW/cm², 999.9 mJ/cm²) for ...
  • Max Average Power: 4 W
  • Effective Aperture: -- mm
  • Spectral Range: 0.356 - 0.436 um
  • Cooling Method: No cooling
Data Sheet
Model 357 UV Light Intensity & Energy Meter For Wafer Steppers
OAI
Designed for use with ASML, Nikon, Canon, GCA & Rudolph Technology Wafer Steppers, the Model 357 UV Light Intensity & Energy Meters is a microprocessor based instrument that performs measurement, storage, and recall of nine series of readings. It reads intensity, energy, and time (16-1600 mW/cm², 999.9 mJ/cm²x). For 400 and ...
  • Max Average Power: 1.6 W
  • Effective Aperture: -- mm
  • Spectral Range: 0.365 - 0.540 um
  • Cooling Method: No cooling
Data Sheet
Model 308T Handheld UV High Intensity Light Meter
OAI
Built for high intensity applications the NEW OAI Model 308T UV Light Meter is a dependable, direct-reading instrument designed for measuring UV light intensity for UV curing. The Model 308T features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port. Accuracy of the meter is within ±3%and ...
  • Max Average Power: -- W
  • Effective Aperture: -- mm
  • Spectral Range: 0.365 - 0.540 um
  • Cooling Method: No cooling
  • Relative Accuracy 275-2000 Mw/cm2 Range: ±(.042% of reading +.450 mw/cm2 ) 
Data Sheet
Model 308 Handheld UV Light Meter
OAI
Dependable and repeatable, The OAI Model 308 UV Light Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data ...
  • Max Average Power: -- W
  • Effective Aperture: -- mm
  • Spectral Range: 0.365 - 0.540 um
  • Cooling Method: No cooling
  • Relative Accuracy 275-2000 Mw/cm2 Range: ±(.042% of reading +.450 mw/cm2) 
Data Sheet
The PRONTO-50-W5 and PRONTO-250 Portable Laser Probes from Gentec-EO are pocket-size power and energy meters with built-in display. The PRONTO-50-W5 and PRONTO-250 give accurate measurement of laser power up to 50 W and 250 W in only 5 seconds. In addition to the regular Single Shot Power (SSP) mode, The PRONTO-250-PLUS features 2 ...
  • Max Average Power: 50 W
  • Effective Aperture: 19 mm
  • Spectral Range: 0.19 - 10 um
  • Cooling Method: No cooling
  • Noise Level: 4 mW 
Data Sheet
The PRONTO-50-W5 and PRONTO-250 Portable Laser Probes from Gentec-EO are pocket-size power and energy meters with built-in display. The PRONTO-50-W5 and PRONTO-250 give accurate measurement of laser power up to 50 W and 250 W in only 5 seconds. In addition to the regular Single Shot Power (SSP) mode, The PRONTO-250-PLUS features 2 ...
  • Max Average Power: 250 W
  • Effective Aperture: 19 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: No cooling
  • Noise Level: 10 mW 
Data Sheet
The PRONTO-50-W5 and PRONTO-250 Portable Laser Probes from Gentec-EO are pocket-size power and energy meters with built-in display. The PRONTO-50-W5 and PRONTO-250 give accurate measurement of laser power up to 50 W and 250 W in only 5 seconds. In addition to the regular Single Shot Power (SSP) mode, The PRONTO-250-PLUS features 2 ...
  • Max Average Power: 250 W
  • Effective Aperture: 19 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: No cooling
  • Noise Level: 10 mW 
Data Sheet
The Gentec-EO HP Series power detector family includes HP100A-4KW-HE, HP60A-10KW-GD and HP100A-12KW-HD, HP125A-15KW-HD. The HP detectors can measure between - 100 W and 4 KW of average power for HP100A-4KW-HE & HP100A-4KW-HE-TUBE - 300 W and 10 KW of average power for HP60A-10KW-GD - 300 Wand 12 KW of average power for ...
  • Max Average Power: 15000 W
  • Effective Aperture: 125 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water
Data Sheet
The Gentec-EO HP Series power detector family includes HP100A-4KW-HE, HP60A-10KW-GD and HP100A-12KW-HD, HP125A-15KW-HD. The HP detectors can measure between - 100 W and 4 KW of average power for HP100A-4KW-HE & HP100A-4KW-HE-TUBE - 300 W and 10 KW of average power for HP60A-10KW-GD - 300 Wand 12 KW of average power for ...
  • Max Average Power: 12000 W
  • Effective Aperture: 125 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water
Data Sheet
The Gentec-EO HP Series power detector family includes HP100A-4KW-HE, HP60A-10KW-GD and HP100A-12KW-HD, HP125A-15KW-HD. The HP detectors can measure between - 100 W and 4 KW of average power for HP100A-4KW-HE & HP100A-4KW-HE-TUBE - 300 W and 10 KW of average power for HP60A-10KW-GD - 300 Wand 12 KW of average power for ...
  • Max Average Power: 4000 W
  • Effective Aperture: 125 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification.  The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 6 W
  • Effective Aperture: 17 mm
  • Spectral Range: 0.19 - 10 um
  • Cooling Method: No cooling
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification.  The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 6 W
  • Effective Aperture: 17 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: No cooling
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 2 W
  • Effective Aperture: 10 mm
  • Spectral Range: 0.28 - 21 um
  • Cooling Method: No cooling
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 2 W
  • Effective Aperture: 10 mm
  • Spectral Range: 0.28 - 21 um
  • Cooling Method: No cooling
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 2 W
  • Effective Aperture: 10 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water, Heatsink, Fan-cooled
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 2 W
  • Effective Aperture: 10 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: No cooling
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 70 W
  • Effective Aperture: 12 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water, Heatsink
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 20 W
  • Effective Aperture: 12 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water, Heatsink
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 10 W
  • Effective Aperture: 12 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: No cooling
Data Sheet
The Gentec-EO UP series of laser power detectors include seven families (XLP12, UP12, UP10, UP17, UP19, UP25, UP55) of opto-thermal sensors with different cooling options (stand alone, heat sink, fan and water), with or without amplification. The high power surface absorber sensors are designed for use at high average power ...
  • Max Average Power: 500 W
  • Effective Aperture: 55 mm
  • Spectral Range: 0.19 - 20 um
  • Cooling Method: Water, Heatsink, Fan-cooled
Data Sheet