No parameters available.

Photonic Doppler Velocimeter : for more reliable measurement on your high speed phenomena  IDIL Fibres Optiques developed the first industrial Photonic Doppler Velocimeter for shocks and detonic applications. This technology allows to measure unique or multiple speeds, in the range of 0 to 20 km/s with an excellent ...
  • Speed Uncertainty: +/- 3 m/s for 50 ns m/s
  • Displacement Interferometer: High dynamics (>27 dB) 
  • Ethernet Interface: (function of the width of the Fourier window analysis) 
  • Speed Uncertainty: +/- 0.5 m/s for 300 ns m/s
  • Measurement Channel: Up to 4 measurement channels 
  • ...
Data Sheet
Precise USB2.0 device combining the functionality of autocollimator and alignment telescope with laser beam profiling capability. The system measures minute angular displacements for various optical setups and alignment tasks, as well as laser beam divergence analysis. The system offers portable, compact and accurate beam ...
Data Sheet
The Adjustable Lateral Offset device (LOD) is used to perfectly cancel offset between two optical line of sights: The paralax cancelling is perfectly preserving parallelism between original lines of sightStandard +/- 3 arc secMonolithic designThe LOD is mounted on a concentric dual axis rotational device, capable of rotating the ...
Data Sheet
High precision beam diagnostics for CW lasers up to 4 kWatts. A wide spectral range from deep UV through 2700 nm. Wide dynamic range, beam size measurements down to several microns and up to 9 mm. This is a complete system for high laser power measurement, including a beam sampler, the measuring head and ...
Data Sheet
OEwaves’ Ultra-Narrow Laser Linewidth and Frequency Noise Measurement System utilizes a homodyne methodology for automated measurement capable of testing ultra-low phase noise laser sources. The user friendly test system is capable of rapidly measuring <10 Hz Lorentzian linewidth of a laser source without the complicated setup ...
  • Offset Frequency Range: 1-100M Hz
  • System Rack-Mount: 19 in
  • Frequency Noise Floor: <1 Hz/rt-Hz
  • Linewidth Sensitivity: 10 Hz
Data Sheet
A portable, fast and accurate optical beam positioning system having a USB2.0 interface. The system is based on a 24 bit A/D electronics box, powered via the  USB2.0 port. It offers simultaneous operation of one or two PSD\'s in one system. The PSD\'s are Lateral Effect type or Four-Quadrant type.  ...
  • Detector Size: 10 x 10 mm
  • Usable Beam Size: 50 - 8000 micrometer
  • Position Resolution: Down to 0.25% of Beam Size 
  • Update Rate: Max 150Hz at 500Hz digital filter 
  • Spectral Range: 350 - 1100 nm
  • ...
Data Sheet
Simultaneous measurements of position and angular displacements. The system offers real time measurements of beam position and angular displacements as well as power display, with resolution down to 0.1 um. The system measures CW beams, and offers portable, fast and accurate beam alignment solution. It is a USB2.0 device, the system ...
  • Usable Beam Size Range: 50 - 8000 mm
  • Temperature Range: 0 - 35 Celsius
  • Update Rate: Max 150Hz at 500Hz digital filter 
  • Spectral Range: 350 - 1100 nm
  • Position Measurement Range : 8 dia circle max mm
  • ...
Data Sheet
Swamp Optics offers compact, convenient FROG devices for measuring ultrashort laser pulses in real time and which yield the most complete measurements ever and include the beam spatial profile and spatio-temporal distortions.  Awards include an R&D100 award and a Circle of Excellence award.  Swamp Optics also offers ...
Data Sheet
UV converter by DataRay Inc used in light source diagnostic applications. 
Data Sheet
Near infrared (NIR) image converter by DataRay Inc. ƒƒThis converter provides the following features:- Extends the range of our standard silicon cameras into the near-infrared 1480 to 1605 nmƒƒ- No image fading or lag timeƒƒ- Cost effective for beams ≥ 500 μmƒƒ- High quality AR coated optics
Data Sheet
Reflective attenuator by DataRay Inc. 
Data Sheet
Reflective attenuator by DataRay Inc. 
Data Sheet
Wedge beam splitter cube by DataRay Inc. The CUB beam splitter cube takes a fixed ratio beam sample. It uses the front surface reflection from an  uncoated laser mirror to achieve a reflection of 3% to 10% of the main laser beam for further analysis. The surface is polished to 10-5 scratch-dig and 1/10 wave finish, wedged ...
Data Sheet
Wedge beam splitter cube by DataRay Inc. The CUB beam splitter cube takes a fixed ratio beam sample. It uses the front surface reflection from an  uncoated laser mirror to achieve a reflection of 3% to 10% of the main laser beam for further analysis. The surface is polished to 10-5 scratch-dig and 1/10 wave finish, wedged ...
Data Sheet
Variable attenuator (neutral density filter) wheel by DataRay Inc. 4x4 position wheels, 93 dB optical dynamic range, 350 to 2200 nm.This is a simple-to-use variable attenuator. It consists of a bank of four filter wheels, each with three different filters ranging from 100% transmission down to 0.003 %. This filter bank ...
Data Sheet